VENTING FIREPLACE - TOP (continued)
Warning
: Use flue restrictor for vertically terminated units only.
Do not use for horizontally terminated units.
Figures 47 to 49
show the location and recommended openings
for the flue restrictor. Adjustments may be made for each
particular installation.
Figure 47
Note:
When installing flue restrictor, install with screws pointing
in downward position.
LP Setting - Figure 48
Natural Gas Setting - Figure 49
Below Grade Installation
When it is not possible to meet the required vent termination
clearances of 12” (305 mm) above grade level, a snorkel kit is
recommended. It allows installation depth down to 7” (178 mm)
below grade level. The 7” (178 mm) is measured from the center of
the horizontal vent pipe as it penetrates through the wall.
Ensure the sidewall venting clearances are observed. If venting
system is installed below ground, we recommend a window
well with adequate and proper drainage to be installed around
the termination area.
3” (76mm)
MINIMUM
PIPE STRAP
48”
(1219mm)
COMBUSTIBLE
PROJECTION
18” (457mm)
MINIMUM
12” (305mm)
ABOVE GRADE
TYPICAL BASEMENT INSTALLATION
TYPICAL BASEMENT INSTALLATION
Figure 50
Summary of Contents for DVCC32LP
Page 39: ...32261 5 0414 Page 39 Figure 77 MILLIVOLT STANDING PILOT WIRING DIAGRAM BP3 SERIES ...
Page 46: ...32261 5 0414 Page 46 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING BP7 SERIES ...
Page 47: ...32261 5 0414 Page 47 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING BP7 SERIES ...
Page 51: ...32261 5 0414 Page 51 MILLIVOLT PARTS VIEW DVCP 32 36 42 BP3 ...
Page 53: ...32261 5 0414 Page 53 IP PARTS VIEW DVCP 32 36 42 BP7 ...