32261-5-0414
Page 24
INSTALLATION (continued)
VERTICAL, 90 DEGREE ELBOW TO HORIZONTAL OUT THE
WALL (12” minimum rise before elbow)
90° ELBOW
“A”
PIPE
LENGTH
VENT CAP
WALL FIRESTOP/
THIMBLE
“B”
“C”
"A"
"B"
"C"
6"
11-1/4” to 12-3/4”
(286mm to 324mm)
4-3/4” to 6-1/4”
(121mm to 159mm)
9"
14-1/4” to 15-3/4”
(362mm to 400mm)
7-3/4” to 9-1/4”
(197mm to 235mm)
12"
17-1/4” to 18-3/4”
(438mm to 476mm)
10-3/4” to 12-1/4”
(273mm to 311mm)
Figure 44
CORNER INSTALLATION - VERTICAL, 90 DEGREE ELBOW
TO HORIZONTAL OUT THE WALL(12” minimum rise before
elbow)
WALL FIRESTOP/
THIMBLE
VENT
CAP
6” (152 mm)
MINIMUM
9” (229 mm)
MINIMUM
Dim.
DVCP32
DVCP36
DVCP42
A
37-3/4”
(959 mm)
39-7/8”
(1012 mm)
44-1/8”
(1121 mm)
B
26-3/4”
(679 mm)
28-3/16”
(716 mm)
31-3/16”
(792 mm)
C
12-3/4”
(324 mm)
13-3/4”
(349 mm)
15-15/16”
(405 mm)
D
53-3/8”
(1356 mm)
56-3/8”
(1432 mm)
62-3/8”
(1584 mm)
Figure 45
Summary of Contents for DVCC32LP
Page 39: ...32261 5 0414 Page 39 Figure 77 MILLIVOLT STANDING PILOT WIRING DIAGRAM BP3 SERIES ...
Page 46: ...32261 5 0414 Page 46 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING BP7 SERIES ...
Page 47: ...32261 5 0414 Page 47 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING BP7 SERIES ...
Page 51: ...32261 5 0414 Page 51 MILLIVOLT PARTS VIEW DVCP 32 36 42 BP3 ...
Page 53: ...32261 5 0414 Page 53 IP PARTS VIEW DVCP 32 36 42 BP7 ...