CLEARANCES
Clearance to Combustibles
Back
0" (0 mm)
Side
0" (0 mm)
Floor
0" (0 mm)
Top Stand-off
0" (0 mm)
Top Framing Edge 3" (76 mm)
SEE MANTLE CHART FOR
MAXIMUM MANTLE DEPTH
NAILING
FLANGES
GLASS FRONT
TOP FRAMING
LEDGE
FINISHED WALL
(COMBUSTIBLE)
SEE MANTLE CHAR
FOR MINIMUM HEIGHT
OF MANTLE ABOVE UNIT
2" x 4" HEADER
STAND OFF
3" (76 mm) HEIGHT
ABOVE TOP OF
FIREPLACE
NAILING
FLANGES
STAND OFF
ABOVE TOP
FIREPLACE
Figure 27
Combustible Material
No greeting cards, stockings or ornamentation of any type should
be placed on or attached to the fireplace. The flow of heat can
ignite combustibles.
Note: When using Empire EMBF, UMC, and UMF Series Full Man
-
tels, combustible clearance may be reduced to 1” clearance from
top edge of fireplace face.
FRONT FACE (SIDE)
FIREPLACE
(TOP VIEW)
3
MAX.
PERPENDICULAR
SIDE WALL
45°
6
COMBUSTIBLE
MATERIALS ALLOWED
IN SHADED AREAS
Figure 28
Mantel Chart
INDEX
LETTER
DISTANCE FROM TOP
EDGE OF FIREPLACE
(HORIZONTAL)
DISTANCE FROM
FIREPLACE FRONT
(VERTICAL)
A
15” (381mm)
12” (305mm)
B
15” (381mm)
10” (254mm)
C
13-3/4” (349mm)
8” (203mm)
D
11” (279mm)
6” (152mm)
E
8” (203mm)
3-3/4” (95mm)
F
6” (152mm)
2-1/4” (57mm)
G
3” (76mm)
0” (0mm)
Figure 29
Clearances
WARNING
This fireplace is not been tested nor approved to have a television
or other electrical appliance installed above it.
Clearance from top front edge of fireplace to ceiling is 36”
Clearance from side of fireplace to adjacent sidewall is 6”.
Figure 30
Summary of Contents for DVCC32LP
Page 39: ...32261 5 0414 Page 39 Figure 77 MILLIVOLT STANDING PILOT WIRING DIAGRAM BP3 SERIES ...
Page 46: ...32261 5 0414 Page 46 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING BP7 SERIES ...
Page 47: ...32261 5 0414 Page 47 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING BP7 SERIES ...
Page 51: ...32261 5 0414 Page 51 MILLIVOLT PARTS VIEW DVCP 32 36 42 BP3 ...
Page 53: ...32261 5 0414 Page 53 IP PARTS VIEW DVCP 32 36 42 BP7 ...