Page 26
36776-4-0117
TABLE 3 - MINIMUM DIMENSIONS (in inches) FOR FIGURES 34 - 36
Model
A
B
C
D
E
F
VFLL60FP
41-1/4
65
11
61-3/4
87-1/4
43-3/4
VFLL72FP
41-1/4
77
11
70-3/16
99-1/4
49-3/4
* Minimum clearance with 1/2-inch non-combustible board over face of fireplace.
C
A
B
Figure 34 - Rough Opening for Installing in Wall
A
C
B
Figure 35 - Rough Opening for Elevated Installation
Figure 36 - Rough Opening for Installing in Corner
1. Frame in rough opening.
•
This fireplace is designed to be mounted on a hard,
flat surface or raised platform.
•
Use dimensions shown in Figure 34 for a conventional
rough opening.
•
Use Figure 35 for an elevated installation. Provide
support to the bottom of the fireplace.
•
Use dimensions shown in Figure 36 for corner rough
opening. Be sure to provide gas line and electrical
power for fireplace assembly.
2. Refer to Junction Box Wiring section on page 17 for details
on electrical requirements.
3. Verify gas and electrical lines are ready for fireplace
installation. (See Gas Supply Page 18)
FRAMING - FLUSH MOUNT