1.  General 

Before using the 

training equipment for the 

first time, 

read this user manual with all the safety 

instructions and warnings carefully to ensure safe and proper use. Keep this document for future 
reference and give it to others if you pass on the equipment. 

 

 

The purpose of the equipment is cardiopulmonary training and the reproducible loading of the 

body, e.g. for diagnostic and therapeutic measures. The equipment is mainly used by users in cardiology, 
physiotherapy, sports medicine and in the home. Another application is the use to build up and strengthen skeletal 
muscles, as well as to increase mobility in the joints affected during training.  
The equipment enables reproducible physical loading of the human body and the cardiovascular system for the 
purposes of prevention, rehabilitation and diagnosis.   
 
Text with a grey background indicates text sections that deal exclusively with equipment features of the fitness line.  

2.  Classification of the devices  

  The devices of the 

cardio line med 

are medical devices according to the directive 93/42 EWG, classified in class 

IIa. In the control range of the brake, the display accuracy is +/- 5%. 

  The  devices  of  the 

cardio  line 

comply  with  the  standard  DIN  EN  ISO  20957-1  and  DIN  EN  ISO  20957-5; 

application  class  S  (commercial  use/studio)  and  H  (home  use)  of  accuracy  class  A  +/-  10  %  and  are  designed 
exclusively for the fitness and sports sector.  

 

 
Only 1 person can exercise with the equipment at a time; the maximum user weight according to the type plate must 
not be exceeded. 

Summary of Contents for motion cross 900

Page 1: ...Instruction elliptical trainer 900 900 med Version 1 1 07 06 2022 Page 1 from 13 Instructions for use for motion cross 900 motion cross 900 med...

Page 2: ...ning 5 Indications and contraindications 6 4 Operating the display 7 Overview display key functions 7 Pulse systems 8 Inductive charging optional 8 5 Care maintenance and servicing 8 Instructions for...

Page 3: ...n the joints affected during training The equipment enables reproducible physical loading of the human body and the cardiovascular system for the purposes of prevention rehabilitation and diagnosis Te...

Page 4: ...stallation of the equipment Fig 1 Side view of the unit with designation of the essential elements Adjustable feet for levelling Pedals Position name plate Rigid hand grips for support during lower li...

Page 5: ...n training tight fitting lightweight sports clothing is preferable so that it cannot get caught in parts of the device during training Always wear suitable sports shoes for a secure footing on the ped...

Page 6: ...o disconnect it e g by means of floor tanks installation under the unit or cable ducts position of the power supply in areas that are difficult to access Warning If the medical device is modified appr...

Page 7: ...se the key or key to increase or decrease the parameters or power values to be set Use the arrow keys to navigate through the corresponding menus and confirm values or settings Swipe swipe gestures na...

Page 8: ...arging optional An optional inductive charging module can be activated on all motion cardio line 900 and motion cardio line 900 med units via the connect package This allows mobile devices that comply...

Page 9: ...imitation ISO 7010 W001 General warning sign ISO 7010 M002 Follow the operating instructions IEC 60417 5840 Type B applied part concerns saddle pedals and handlebars The safety level of the units can...

Page 10: ...rom the PC after the specified time period Restart the PC and plug the USB dongle into the PC again If necessary restart the software service All ergometers Radio Problem verbos The unit does not rece...

Page 11: ...h a damp cloth and mild soap then wipe dry again The use of spray bottles with cleaning agents is not permitted it has been shown that the units never become dry in inaccessible places Rust infestatio...

Page 12: ...and regulations at the location of the units Your local authorised dealer can also provide further information 6 Technical data Device type Dimensions L W H Weight Max user weight Safe workload motion...

Page 13: ...e of service The following procedures are conceivable 1 the service is carried out on site by our service 2 we send the desired spare part 3 we will send a replacement unit The defective parts shall b...

Reviews: