1. TITOLO
2. USE OF HEAT PUMP
GB
GB
Models
Ref.
u.m.
EQ 1015 W
Thermal power (average) output from the heat pump (external air DB/WB: 7/6 °C)
kW
0,76**
Electrical power (average) absorbed by the heat pump (external air DB/WB: 7/6 °C)
kW
0,21**
R134a refrigerant (GWP = 1300)
g
540
Sound Power Level inside
dB(A)
54* / 51**
Sound power level outside
dB(A)
52**
Electricity Supply
230 V ~ 50 Hz
Maximum Power Absorbed
kW
2,35
Maximum Current
A
10,5
Electrical heater power
kW
2,00
Air flow
m
3
/h
100 -230
Useful static pressure
Pa
70-90
Nominal tank capacity
l
100
Water attachments
Ø
1/2"
Maximum operating pressure
bar
6
Dimensions
LxDxH
mm
533x506x1342
Degree of protection
IP24
Empty weight
Kg
62
* Installation not ducted with intake and exaust air from indoor
** Installation ducted with intake and exaust air from outdoor
OPERATING RANGE
EQ 1015 W
Models
Ref.
u.m.
Inlet air temperature
°C
-7 ÷ 35
Water temperature (heat pump)
°C
10 ÷ 75
Local installation temperature
°C
10 ÷ 35
Minimum Volume of the installation location
m
3
30