30
1. TITOLO
2. USE OF HEAT PUMP
2. USE OF HEAT PUMP
GB
GB
THE PRINCIPLE OF OPERATION
The heat pump is in fact a thermodynamic heat generator, drawing heat from a low temperature level (e.g.: heat
from the ambient air) to a higher temperature level (e.g.: hot sanitary water).
The heat drawn from the ambient air, along with the electric energy, generates heating energy, which is available
for heating the sanitary water.
Fig. 2: Connection and installation dimensions of the heat pump [mm]
Dimensions
A
B*
C*
D*
E*
EQ1015W
1342
490
100
100
G 1/2
* DIN norm
2/3 Heat from
ambient air
Produced hot
sanitary water
+ 55 °C
Compressor
1/3 Electric
energy
Condensator
Evaporator
Flow control element
Fig. 1: Chart of energy flow through the heat pump unit
A
264
B
589
C
294
350
350
D
E
324
506
533
285
170
Air inlet
Air outlet
DHW Cold
DHW Hot
Discharge
Ø 18 mm
Front View