32
1. TITOLO
2. USE OF HEAT PUMP
2. USE OF HEAT PUMP
GB
GB
INSTALLATION OF THE HEAT PUMP
The heat pump can be used using the ambient air or air from other premises. The heat pump must be installed in
a frost-free room. When selecting a place for installation, particular attention should be paid that the selected air
intake location is dust free, because dust has adverse effects on the heat pump performance. When selecting the
place of installation, pay attention to the solidity of the wall – can it take the weight of the heat pump together
with the weight of the water inside the boiler?
Take all the necessary precautions to prevent the operation noise and vibrations from transferring through the
walls to the premises where this would be disturbing (bedrooms, rest areas). Do not install the heat pump and
its air intake in premises with other air consumption appliances (gas boilers, solid-fuel fireplaces, dust extraction
appliances etc.) During installation, please bear in mind the minimum distances from the wall, ground and cei-
ling. The condensate outlet from the heat pump is placed on the bottom left side in the form of a plastic tube with
an external diameter of Ø18 mm. This tube should be connected to the external condensate outlet pipe and
led to the sewage system or a container. The quantity of condensate depends on air temperature and humidity
when the heat pump is in operation.
Fig. 3: Ventilation
To minimize the transfer of noise and vibrations through walls into the premises where this would be disturbing
(bedrooms, rest areas), please take the following measures:
- install flexible joints for hydraulic connections
- install a flexible tube for the pipeline of inlet/outlet air
- plan vibration insulation for wall openings
- plan noise dampers for inlet/outlet air
- pipelines for inlet/outlet air should be attached using noise dampers
- plan vibration insulation against the wall
Is not allowed.
To prevent pressure depression in the building, fresh
air must be regularly supplied to the premises.
The desired rate of air exchange for a residential
building is 0.5. This means that the entire quantity
of air in the building is exchanged every two hours.
Connecting the heat pump to the same pipeline as
the kitchen extractor fan or taking air out of several
smaller apartments or suites