29
=
=
Or
=
=
Or
Manual Reset-2.
Device continues to count till manual reset is applied.
(Output pulse Time is not considered)
Counting direction : 0 --> P (Upcounting)
=
When count value reaches the Set Value, Output Position is changed.
Counting process is not continue over the SET value
.
Output Pulse Time
is not considered. Process counts, until manual reset happens. When
Manual Reset happens, count value becomes 0 value. Counting is
continues, while Start input is active. When Start input is passive, count
value becomes “0”.
Counting direction : P --> 0 (Downcounting)
=
When count value reaches the 0, Output Position is changed.
Counting process is not continue under the 0 value
.
Output Pulse Time
is not considered. Process counts, until manual reset happens. When
Manual Reset happens,
Counting is
continues, while Start input is active. When Start input is passive, count
value becomes SET value.
count value becomes SET value.
0
Set
Reset
Output
Start
0
Set
Reset
Output
Start