30
6. Specifications
Device Type
Housing&Mounting
Protection Class
Weight
Environmental Ratings
Storage / Operating Temperature
Storage / Operating Humidity
Installation
Overvoltage Category
Pollution Degree
Operating Conditions
Supply Voltage and Power
Temperature Sensor Inputs
NTC Input Type
PTC Input Type
Thermocouple Input Types
Thermoresistance Input Type
Accuracy
Cold Junction Compensation
Sensor Break Protection
Sampling Cycle
Control Form
Relay Output
Optional SSR Output
Display
LED
Internal Buzzer
Approvals
: Heating Controler
: 35 mm x 77 mm x 62.5 mm plastic housing for panel
Mounting. Panel cut-out is 71 x 29 mm
: Ip65 at front, IP20 at rear)
: Approximately 0.20 Kg.
: Standard, indoor at an altitude of less than 2000 meters
with none condensing humidity
: -40 C to +85 C / 0 C to +50 C
: 90 % max. (None condensing)
: Fixed installation
: II.
: II, office or workplace, none conductive pollution
: Continuous
:
V
(± 15%) 50/60 Hz. 1.5
V
(± 15%) 50/60 Hz. 1.5
24 V
(± 15%) 50/60 Hz. 1.5
V
(- %15, + %10) 50/60 Hz. 1.5
V
(± %15) 50/60 Hz. 1.5
: NTC, PTC, TC, RTD
: NTC (10 k @.25 °C)
: PTC (1000
@.25 °C)
: J, K (IEC584.1)(ITS90)
: PT-100, PT-1000 (IEC751)(ITS90)
: ±1 % of full scale for thermocouple and thermoresistance
: Automatically ± 0.1°C/1°C
: Upscale
: 3 samples per second
: ON / OFF
:
A@250 V
for resistive load
(Electrical Life : 100.000 switching at full load)
: Maximum 15 mA@5V
: 14 mm Red 3 digits LED Display
: SV (Green), Output (Red), PR (Red),
Cooking Time Active (Red) 3 mm Led
: 83dB
:
,
o
o
o
o
230
VA
115
VA
VA
24
VA
12
VA
10
V
V
V
W
W
V
Z
W
W
³