7. Other Informations

Manufacturer Information:

Emko Elektronik Sanayi ve Ticaret A.Þ.
Demirtaþ Organize Sanayi Bölgesi Karanfil Sk. No:6 16369 
BURSA/TURKEY

Phone   : +90 224 261 1900
Fax  : +90 224 261 1912

Repair and Maintenance Service Information:

Emko Elektronik Sanayi ve Ticaret A.Þ.
Demirtaþ Organize Sanayi Bölgesi Karanfil Sk. No:6 16369 
BURSA/TURKEY
Phone   : +90 224 261 1900
Fax  : +90 224 261 1912

Thank you very much for your preference to use Emko Elektronik 

Products.

Your Technology Partner

www.emkoelektronik.com.tr

32

Summary of Contents for ESM-3711-CL

Page 1: ...operates periodically in case of probe defect Compressor protection delays Defrost Off Cycle function Adjustable defrost time from front panel Manual defrost from front panel Defrost parameters Alarm...

Page 2: ...xplained Operation Also in these sections there are warnings to prevent serious injury while doing the physical and electrical mounting or using the device Explanation of the symbols which are used in...

Page 3: ...TPUT CONNECTION 4 FRONT PANEL DEFINITION AND ACCESSING TO THE MENUS 4 1 4 2 CHANGING AND SAVING TEMPERATURE SET VALUE 4 3 CHANGING AND SAVING DEFROST TIME SET VALUE 4 4 PROGRAMMING MODE PARAMETERS LIS...

Page 4: ...nd laboratory use Conforms to the following directives 2006 95 EC The Low Voltage Directive 2004 108 EC The Electromagnetic Compatibility Directive has been designed and manufactured to the following...

Page 5: ...Input Digital Input 1 1 General Specifications 1 Preface ESM 3711 CL series cooling controllers are designed for controlling cooling process They can be used in many applications with their easy use O...

Page 6: ...y period starts from the delivery date This warranty is in force if duty and responsibilities which are determined in warranty document and instruction manual performs by the customer completely 1 4 M...

Page 7: ...eep the power off until all of the wiring is completed so that electric shock and trouble with the unit can be prevented Never attempt to disassemble modify or repair this unit Tampering with the unit...

Page 8: ...oling Controller ESM 3711 CL SET C SV PR Max Min 2 1 General Description 2 2 Front View and Dimensions of ESM 3711 CL Cooling Controller Mounting Clamp Front Panel IP65 protection NEMA 4X Panel surfac...

Page 9: ...110 mm 4 33 inch min 50 mm 1 97 inch min 29 mm 1 14 inch 71 mm 2 79 inch 9 Maximum 15 mm 0 59 inch 58 5 mm 2 30 inch 4 mm 0 16 inch 2 3 Panel Cut Out...

Page 10: ...unting the device in your panel make sure that the cut out is of the right size 2 Insert the device through the cut out If the mounting clamps are on the unit put out them before inserting the unit to...

Page 11: ...n the panel cut out from the front side 2 Insert the mounting clamps to the fixing sockets that located left and right sides of device and make the unit completely immobile within the panel Before sta...

Page 12: ...e installer to ensure that the configuration is correct Device parameters has factory default values These parameters must be set according to the system s needs Only qualified personnel and technicia...

Page 13: ...ed in order 12 V W 15 50 60 Hz 1 5 VA P N ESM 3711 CL OUTPUT NO NC C 10A 250V V NTC PTC PT 100 PT 1000 1 2 3 4 5 6 7 8 9 10 11 12 L N 13 CAT II Y c 24 V W 15 10 50 60 Hz 1 5 VA Door Switch DIGITAL INP...

Page 14: ...5VA 3 4 1 5 NO NC C 10A 250V V 6 7 8 9 10 11 12 CAT II PT 100 19 9 to 99 9 Scale C L N L N OUTPUT 230 VV 15 50 60Hz 1 5VA NO NC C 10A 250V V DIGITAL INPUT DIGITAL INPUT 3 3 View of the Device Label D...

Page 15: ...Supply voltage range must be determined in order While installing the unit supply voltage range must be controlled and appropriate supply voltage must be applied to the unit Controlling prevents damag...

Page 16: ...tance is greater than 10 M W i i Pay attention the cable colours of PTC probe while doing the PTC probe connection i i 3 5 3 PT 100 and PT 1000 Connections Input resistance is greater than 10 M W i i...

Page 17: ...SSR Driver Output 2000 V V 2000 V V 2000 V V 2000 V V 2000 V V ESM 3711 CL 5 500 V V ESM 3711 CL 3 1 2 3 1 2 11 9 10 Ground 12 Output 1 Relay Output 1 2 3 1 2 Analogue Input 11 Optional SSR Driver Ou...

Page 18: ...Element SSR 2 Device L N 1 Fuses must be selected according to the application c c Max 15 V Z Max 15mA Fuses must be selected according to the application c Device 1 Load L N 2 Max 10 A V T Fuse NC C...

Page 19: ...t or decrement button is pressed for 10 seconds continuously increment and decrement number become 100 Note 2 In defrost time set value changing mode defrost led is blink fast 5 Hz It is used to enter...

Page 20: ...defrost output led starts to fast blink 5 Hz Press set button for saving the defrost time set value Defrost time set value is saved defrost output led stop the fast blink 5 Hz main operation screen i...

Page 21: ...ound set value changes according to controlled system For reducing oscillation period of temperature value a threshold zone is formed below or around set value and this zone is named hysteresis ON OFF...

Page 22: ...99 minutes Compressor Start Start Delay Parameter Default 0 This time delay must be expired between two activation of the compressor It can be adjusted from 0 to 20 minutes MinimumAlarm Parameter Defa...

Page 23: ...ot active It can be adjusted from 0 to 99 minutes Default 0 Minimum Maximum Temperature logging start option After Power On Parameter It can be adjusted from 1 to 99 Default 1 When power is first appl...

Page 24: ...creen In main operation screen If decrement and SET buttons are pressed together the message is shown on the display after 5 seconds pressing these buttons display starts to blink and the maximum and...

Page 25: ...button C 2 If is 1 1 and Compres r Start Start Delay Parameter is 1 then Compressor Start Delay at Power On Parameter Compressor Stop Start Delay Parameter is Power Time Hst SET Time Output Time Time...

Page 26: ...Main Operation Screen Maximum Set Value Process Offset Defrost Time Defrosting Repeat Cycle Defrost at Power Defrost Delay at Power On Display Status During Defrost Compressor Start Delay at Power On...

Page 27: ...n SET C SV PR Button Protection Max Min SET C SV PR Logging Option Parameter Max Min Logging Starting Time After Door Switch is Closed Max Min SET C SV PR Door Open Alarm Time Max Min SET C SV PR Prog...

Page 28: ...erved instead of programming screen accessing password Press increment button for accessing to the password entering screen Password Entering Screen Press SET OK button for accessing to the parameters...

Page 29: ...ess increment button for accessing to the parameter value Press set button for accessing to the next parameter Press set button for saving the parameter Press set button for accessing to the next para...

Page 30: ...r than the alarm parameters limit value on the screen starts to blink Example 1 If alarm function selection parameter In programming section is 1 Absolute alarm and minimum alarm parameter Is 20 When...

Page 31: ...on Operating Conditions Continuous Supply Voltage and Power 230 V V 15 50 60 Hz 1 5 VA 115 V V 15 50 60 Hz 1 5 VA 24 V V 15 50 60 Hz 1 5 VA 24 V W 15 10 50 60 Hz 1 5 VA 12 V 15 50 60 Hz 1 5 VA Tempera...

Page 32: ...ne 90 224 261 1900 Fax 90 224 261 1912 Repair and Maintenance Service Information Emko Elektronik Sanayi ve Ticaret A Demirta Organize Sanayi B lgesi Karanfil Sk No 6 16369 BURSA TURKEY Phone 90 224 2...

Reviews: