4.2 Changing and Saving Temperature Set Value
Main Operation Screen
When SET button is pressed, SV led
lights on and temperature set value is
shown on the display
Temperature Set Value Screen
Change the temperature
set value with increment
and decrement buttons
Press SET button for saving the
temperature set value
SV led lights off and main operation
screen is shown
When defrost button is pressed,
defrost time set value is shown and
defrost output led starts to fast
blink (5 Hz)
Press set button for saving the
defrost time set value
Defrost time set value is saved, defrost
output led stop the fast blink (5 Hz),
main operation screen is shown
4.3 Changing and Saving Defrost Time Set Value
If no operation is performed in defrost time set value changing mode and
temperature set value changing mode for 20 seconds, device turns to main
operation screen automatically.
i
Change the defrost time set
value with increment and
decrement buttons
Main Operation Screen
Temperature Set Value Screen
Main Operation Screen
Main Operation Screen
Defrost Time Set Value Screen
Defrost Time Set Value Screen
Temperature set value can be adjusted from minimum temperature set value parameter
value to maximum temperature set value parameter value.