Example-2 :
If alarm function selection parameter
in programming section is 1 (Absolute
Alarm) and maximum alarm parameter
is 50
When temperature is above 50 °C, value
on the screen starts to blink. Also buzzer
function selection parameter is 2 or
4, then internal buzzer is on.
5. Failure Messages in ESM-
3711-CL
Cooling Controller
2- Blinking the Screen Value
If temperature higher than the alarm
parameters limit, value on the screen starts
to blink.
Example-1 :
If alarm function selection parameter
In programming section is 1(Absolute
alarm) and minimum alarm parameter
Is 20 ;
When temperature is less than 20°C, value
on the screen starts to blink. Also if buzzer
function selection parameter is 2 or 4,
then internal buzzer is on.
1- Probe failure in analog inputs
Sensor connection is wrong or there is no
sensor connection. When this message is on
the screen, if buzzer function selection
parameter is 3 or 4 , internal buzzer
starts to operate.
3- Blinking the Screen Value and Buzzer
is active
If door switch is remaning open for a long
time than door open alarm time parameter
value, device give the door open alarm
display begins to blink and buzzer will be
active.