Using photo cells
When using photo cell(s) at the finish you
must connect to the double banana plug
marked '
FINISH
'. When the ETS2 is
connected to photo cell(s), it will use the
photo cell as finish time and match this time
to the correct tag number.
Using a start gate
When a start gate is used to register start
times, the start gate must be connected to
the input marked '
START/SYNC
'.
Synchronising several ETS2
Several ETS2 can be synchronized using
the '
START/SYNC
'-input, by short-circuiting this contact (with a switch or a short
cable). All of the ETS2's to be synchronized must be connected to the same
cable AND they must all be in the 'Set Clock'-mode. Use the numeric keys to
set a valid time between 00:00:00 and 23:59:59 (on all ETS2's to be
synchronized). Start the clock simultaneously on all the ETS2's by short-circuiting
the cable connected to the '
START/SYNC
'-inputs.
To check that all ETS2's have been synchronized correctly, short-circuit the cable
once more and check that the time registered is identical on all ETS2s. The time
is printed and shown on the display:
F0-1 09:00:13.954672