10
|
ENGLISH
The default jumper settings for a window/door contact are D0, D1 and D2 (Normal-
group), for the motion detector the default settings are D1 and D2 (Home-group).This
means that the window/door contact will be enabled when the alarm system is in full
security mode or in-home security. The motion detector will only be enabled when the
alarm system is in full security mode. You can enable the full or in-home security by
using the remote control, the “EM8615” APP or by using text messages on your mobile
phone.
When the jumper settings are set to D1 and D2 the sensor is configured in the Home-
group. In full security mode the sensor will be enabled. If In-home security is activated
this sensor will be disabled.
When the jumper settings are set to D1 and D3 the sensor is configured in the Single
group. The Single group has the same functionality as the normal group with an
addition of adding an entry delay time for these sensors.
Remark : Sensors configured in the single group will be enabled in both security
modes (Full, In-home) after a specified time.
When the jumper settings are set to D0, D1 and D3 these sensors are configured as
24-hoursgroup. These sensors are always enabled regardless the status of the
security system.
3.5 Registered sensors
The motion detector and window/door sensor included with the alarm system are
already paired to the system. The motion detector is set by default as Home-group
and the window/door contact is configured as Normal-group.
The window/door contact is paired with Zone 1. The motion detector is paired with
Zone 2.
The supplied remote controls are already paired to the system.
For more information about zones please see chapter “
Change Sensor (zone) name
”