18
English
1. Ensure the On/Off switch (A) is in the OFF position.
2. Allow unit to cool.
3. Remove air filter (M) from unit.
4. Carefully pry filter top from base.
5. Remove element from filter base.
6. If element needs cleaning, blow out with air. Replace if
needed. Purchase replacement parts from your local dealer or
authorized service center. Always use identical replacement
parts.
7. Place element back in filter base.
8. Snap filter top to filter base.
9. Reassemble air filter to unit. Ensure exhaust outlet points
down.
CAUTION:
Risk of unsafe operation. Do not operate without air
inlet filter
Draining Air Tank (Fig. 1)
WARNING:
Risk of unsafe operation. Risk from noise. Air
tanks contain high pressure air. Keep face and other body parts
away from outlet of drain. Use safety glasses
[ANSI Z87.1 (CAN/
CSA Z94.3)]
when draining as debris can be kicked up into face.
Use ear protection
[ANSI S12.6 (S3.19)]
as air flow noise is loud
when draining.
noTE:
All compressed air systems generate condensate that
accumulates in any drain point (e.g. tanks, filter, aftercoolers,
dryers). This condensate contains lubricating oil and/or
substances which may be regulated and must be disposed of in
accordance with local, state, and federal laws and regulations.
1. Ensure
On/Off switch is in the OFF position
.
2. Move compressor into an inclined position so drain valve (H)
is at the lowest point (this will assist in removing moisture,
dirt, etc. from air tanks)
3. Place a suitable container under the drain valve to catch
discharge.
4. Grasp knurled knob on drain valve.
5. Slowly rotate knob to gradually bleed air from air tank.
WARNING:
Risk of bursting.
Drain air tank daily. Water will con-
dense in air tank. If not drained, water will corrode and weaken the
air tank causing a risk of air tank rupture.
NOTICE:
Risk of property damage. Drain water from air tank may
contain oil and rust, which can cause stains.
6. When air tank pressure gauge reads 10 PSI (68,9 kPa), rotate
valve to the fully open position.
7. Close drain valve when finished.
Compressor Pump Oil (Fig. 1)
M
K
L
CHECkInG oIL
WARNING:
Hot surfaces. Risk of burn.
Aftercooler, pump head, and surrounding parts
are very hot, do not touch (see the Hot Surfaces
identified in Fig. 2). Allow compressor to cool
prior to servicing.
1. Ensure
On/Off switch is in the OFF position
.
2. Place unit on a flat level surface.
3. Remove dipstick (K) and wipe clean.
4. Reinsert dipstick fully into oil fill port for a few
seconds to allow oil to collect on the dipstick.
5. Remove oil dipstick to read oil level. Oil should
not exceed top raised line on dipstick. If oil is
below lower mark, add ISO 100/SAE40, non-
detergent, premium air compressor oil and fol-
low Steps 4 - 6.
noTE:
When filling the crankcase, the oil flows
MAX