36C94-303
Delay-Opening Combination Gas Valve
INSTALLATION INSTRUCTIONS
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CARE-
FULLY BEFORE INSTALLING OR OPERATING THIS CONTROL
COULD CAUSE PERSONAL INJURY AND/OR PROPERTY
DAMAGE.
DESCRIPTION
SPECIFICATIONS
36C94-303
is a direct replacement for
36C94-302
,
36E93-301
,
36E93-302
,
36E93-303
and
36E93-304
.
The
36C94-303
combination gas valve is designed
for intermittent ignition system applications. The
valve is equipped with a redundant solenoid valve
that controls gas flow to the pilot and main burners, a
main valve that controls gas flow to the main burner,
a pressure regulator to maintain a constant outlet
pressure, integral gas pressure switch and a two
position on/off switch for electrical shutoff.
Type of Gas:
Natural gas
LP gas (use conversion kit)
Pressure Regulator Adjustment Range:
Nat. Gas
–
2.5 to 5.0"
W.C.
L.P. Gas
–
7.0 to 12"
W.C.
Ambient Temperature
:
–40
to
+175°F
(
–40 to 79°C
)
www.white-rodgers.com
www.emersonclimate.com
PART NO.
37-7086C
Replaces 37-7086B
1305
PIPE SIZE/CAPACITIES
Pipe Size
Available (inches)
Capacity (BTU/hr) at
1
” W.C.
pressure drop across valve
AGA Std. Nat. Gas
(
1,000
btu/ cu. ft.)
LP. Gas
(
2,500
btu/cu. ft.)
1/2" x 3/4"
NPT
230,000
370,000
Pressure Rating:
14"
W.C. (
1/2
PSI) max.
Voltage:
24
VAC
Frequency:
60 Hz
Current:
0.6
A
CONTENTS
Description ................................................
1
Specifications .............................................
1
Precautions ................................................
3
Installation ..................................................
4
Lighting Instructions ...................................
7
French Language .......................................
9
Spanish Language ........................................17