7
FOR YOUR SAFETY READ BEFORE OPERATING
A. This appliance is equipped with an intermittent ignition device which automatically lights the
appliance. Do
not
try to light the pilot by hand.
B.
BEFORE OPERATING
smell all around the appliance area for gas. Be sure to smell next to the
floor because some gas is heavier than air and will settle on the floor.
FOR YOUR SAFETY
“WHAT TO DO IF YOU SMELL GAS”
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call the fire department.
C. Do not use this appliance if any part has been under water. Immediately call a qualified service
technician to inspect the appliance and to replace any part of the control system and any gas
control which has been under water.
WARNING
!
If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
LIGHTING INSTRUCTIONS
OPERATING INSTRUCTIONS
1.
STOP!
Read the safety information above on this page.
2.
Set the thermostat to lowest setting.
3.
Turn off all electric power to the appliance.
4.
This appliance is equipped with an ignition device which automatically lights the burner. Do
not
try to light the burner by hand.
5.
Remove control access panel.
6.
Push On/Off switch to "OFF."
7.
Wait five (
5
) minutes to clear out any gas. If you then smell gas, STOP! Follow “B” in the safety
information above. If you don’t smell gas, go to the next step.
8.
Push On/Off switch to “ON.”
9.
Replace control access panel.
10.
Turn on all electric power to the appliance.
11.
Set thermostat to desired setting.
12.
If the appliance will not operate, follow the instructions “To Turn Off Gas To Appliance” and call
your service technician or gas supplier.
TO TURN OFF GAS TO APPLIANCE
1.
Set the thermostat to lowest setting.
2.
Turn off all electric power to the appliance if
service is to be performed.
3.
Remove control access panel.
4.
Push On/Off switch to “OFF.”
5. Replace control access panel.