Unidrive M100 / M101 Control User Guide
75
Issue Number: 1
10.052
Trip 5 Time
00:00:00 to 23:59:59
RO Time ND
NC PT PS
10.053
Trip 6 Date
00-00-00 to 31-12-99
RO Date ND
NC PT PS
10.054
Trip 6 Time
00:00:00 to 23:59:59
RO Time ND
NC PT PS
10.055
Trip 7 Date
00-00-00 to 31-12-99
RO Date ND
NC PT PS
10.056
Trip 7 Time
00:00:00 to 23:59:59
RO Time ND
NC PT PS
10.057
Trip 8 Date
00-00-00 to 31-12-99
RO Date ND
NC PT PS
10.058
Trip 8 Time
00:00:00 to 23:59:59
RO Time ND
NC PT PS
10.059
Trip 9 Date
00-00-00 to 31-12-99
RO Date ND
NC PT PS
10.060
Trip 9 Time
00:00:00 to 23:59:59
RO Time ND
NC PT PS
10.061
Braking Resistor Resistance
0.00 to 10000.00
Ω
0.00
Ω
RW Num
US
10.065
Autotune Active
Off (0) or On (1)
RO
Bit
ND
NC PT
10.066
Limit Switch Active
Off (0) or On (1)
RO
Bit
ND
NC PT
10.068
Hold Drive Healthy On Under
Voltage
Off (0) or On (1)
Off (0)
RW
Bit
US
10.069
Additional Status Bits
0 to 2047
RO Num ND
NC PT
10.070
Trip 0 Sub-trip Number
0 to 65535
RO Num ND
NC PT PS
10.071
Trip 1 Sub-trip Number
0 to 65535
RO Num ND
NC PT PS
10.072
Trip 2 Sub-trip Number
0 to 65535
RO Num ND
NC PT PS
10.073
Trip 3 Sub-trip Number
0 to 65535
RO Num ND
NC PT PS
10.074
Trip 4 Sub-trip Number
0 to 65535
RO Num ND
NC PT PS
10.075
Trip 5 Sub-trip Number
0 to 65535
RO Num ND
NC PT PS
10.076
Trip 6 Sub-trip Number
0 to 65535
RO Num ND
NC PT PS
10.077
Trip 7 Sub-trip Number
0 to 65535
RO Num ND
NC PT PS
10.078
Trip 8 Sub-trip Number
0 to 65535
RO Num ND
NC PT PS
10.079
Trip 9 Sub-trip Number
0 to 65535
RO Num ND
NC PT PS
10.080
Stop Motor
Off (0) or On (1)
RO
Bit
ND
NC PT
10.081
Phase Loss
Off (0) or On (1)
RO
Bit
ND
NC PT
10.090
Drive Ready
Off (0) or On (1)
RO
Bit
ND
NC PT
10.101
Drive Status
Inh (0), rdy (1), StoP (2), ScAn (3), rES (4),
S.LoSS (5), rES (6), dc.inJ (7), rES (8),
Error (9), ActivE (10), rES (11), rES (12),
rES (13), HEAt (14), UU (15)
RO
Txt
ND
NC PT
10.102
Trip Reset Source
0 to 1023
RO Num ND
NC PT PS
10.103
Trip Time Identifier
-2147483648 to 2147483647 ms
RO Num ND
NC PT
10.104
Active Alarm
NonE (0), br.rES (1), OV.Ld (2), rES (3),
d.OV.Ld (4), tuning (5), LS (6), rES (7),
rES (8), rES (9), rES (10), rES (11),
rES(12), Lo.AC (13), I.AC.Lt (14),
24.LoSt (15)
RO
Txt
ND
NC PT
10.106
Potential Drive Damage
Conditions
0 to 3
RO
Bin
ND
NC PT PS
10.107
Low AC Alarm
Off (0) or On (1)
RO
Bit
ND
NC PT
10.108
Reversed cooling fan detected
Off (0) or On (1)
RO
Bit
ND
PT
RW
Read / Write
RO
Read only
Num Number parameter
Bit
Bit parameter
Txt Text string
Bin
Binary parameter
FI
Filtered
ND
No default value
NC
Not copied
PT
Protected parameter
RA
Rating dependent
US User save
PS
Power-down save
DE Destination
Date
Date parameter
Time Time parameter
Parameter
Range
(
Ú
)
Default
(
Ö
)
Type
OL
OL
Summary of Contents for Unidrive M100