60
Unidrive M100 / M101 Control User Guide
Issue Number: 1
Figure 10-4 Menu 3 Logic diagram
Parameter
Range
(
Ú
)
Default
(
Ö
)
Type
OL
OL
03.001
Final Demand Reference
VM_FREQ Hz
RO Num ND NC PT FI
03.005
Zero Frequency Threshold
0.00 to 20.00 Hz
2.00 Hz
RW Num
US
03.006
At Frequency Lower Limit
0.00 to 550.00 Hz
1.00 Hz
RW Num
US
03.007
At Frequency Upper Limit
0.00 to 550.00 Hz
1.00 Hz
RW Num
US
03.008
Over Frequency Threshold
0.00 to 550.00 Hz
0.00 Hz
RW Num
US
03.009
Absolute At Frequency Select
Off (0) or On (1)
Off (0)
RW
Bit
US
03.022
Hard Frequency Reference
VM_SPEED_FREQ_REF Hz
0.00 Hz
RW Num
US
03.023
Hard Frequency Reference Select
Off (0) or On (1)
Off (0)
RW
Bit
US
03.037
Frequency Output or PWM Output
Scaling (T10)
0.000 to 4.000
1.000
RW Num
US
03.038
Maximum Output Frequency (T10)
1 (0), 2 (1), 5 (2), 10 (3) kHz
5 (2) kHz
RW
Txt
US
03.072
Motor Speed Percent
±150.0 %
RO
ND NC PT FI
RW
Read / Write
RO
Read only
Num Number parameter
Bit
Bit parameter
Txt Text string
Bin
Binary parameter
FI
Filtered
ND
No default value
NC
Not copied
PT
Protected parameter
RA
Rating dependent
US User save
PS
Power-down save
DE Destination
Date
Date parameter
Time Time parameter
mm.ppp
mm.ppp
Key
Read-write (RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
The parameters are all shown in their default settings
T 10 Digital
I
/
O 1
03.037
??.???
??.???
At
Z
ero
F
requency
10.003
Any valid
parameter
M
a
x
imum Output
F
requency
T10 Digital I
/
O 01
Output
S
elect
F
requency Output or
PW
M
Output
S
caling
T10 DO1 Control
T10 DI
/
O
S
ource
/
Destination B
T10 Digital IO1
S
ource
/
Destination A
08.091
08.021
≥
1
03.038
08.031
2 or 3
0 to 1
10
08.121
Summary of Contents for Unidrive M100