66
SI-Safety Installation & Operating Manual
Issue Number: 1
Alarm Code
A 3505 / A 3506
Fault message
SSI Plausibility
Cause
SSI Plausibility is defective
Remedial action
Replace SSI Encoder
Alarm code
A 4001 / A 4002
Anti clockwise and
clockwise motion
monitoring of SDI.1
were enabled
simultaneously
Anti clockwise and clockwise motion monitoring of SDI.1 were
enabled simultaneously
Cause
Multiple activation
Remedial action
When programming the system, ensure that only one ‘Enable’
at a time is activated
Alarm code
A 4003 / A 4004
Alarm message
Anticlockwise and clockwise motion monitoring of SDI.2 were
enabled simultaneously
Cause
Multiple activation
Remedial action
When programming the system, ensure that only one ‘Enable’
at a time is activated
Alarm code
A 4501 / A 4502
Alarm message
Internal fault – please contact the manufacturer
Alarm code
A 4601 / A 4602
Alarm message
Internal fault – please contact the manufacturer
Alarm code
A 4603 / A 4604
Alarm message
Internal fault – please contact the manufacturer
Alarm code
A 4605 / A 4606
Alarm message
SLP1 Teach in state error
Cause
SET and QUIT input have wrong switching sequence
Remedial action
Check input configuration
Check switching sequence
Summary of Contents for unidrive m