Unidrive M / Unidrive HS Modular Installation Guide
Issue Number: 5
2.6 Input line reactor
The INL line reactor must be used in conjunction with the Unidrive M / Unidrive HS rectifiers. See section 6.2.2
Input line reactor specifications
page 93 for further information.
Figure 2-9 Single input line reactor (INLX0X)/force cooled (INLX0XW)
2.7 Output sharing choke
The OTL output sharing choke must be used on the output of Unidrive M / Unidrive HS when more than one module is paralleled together.
Figure 2-10 Single output sharing choke (OTLX0X) - two chokes shown
Figure 2-11 Dual output sharing choke (OTLX1X)
For a physical representation of the input line reactors and output sharing chokes, see section 2.6 and section 2.7
L1
L2
L3
L1A
L2A
L3A
U1
V1
W1
U2
V2
W2
U
V W
U
V W
U1
U2
V1
V2
W1
W2
Drive 1
Drive 2
U1
V1
W1
U2
V2
W2