68
SI-EtherCAT User Guide
Issue Number: 2
Table 7-53 Definition of bits 10 and 12 of the statusword
7.6.2
Homing mode object definitions
0x3003 Homing source
This object indicates the configured source of the homing switch used during the homing
procedure. Table 7-54
on page 68 specifies the object description.
Table 7-54 Homing source
Bit 12
Bit 10
Definition
0
0
Homing procedure is in progress.
0
1
Homing procedure is interrupted or not started.
1
0
Homing is attained, but target is not reached.
1
1
Homing procedure was completed successfully.
0
0
Homing error occurred, velocity is not 0.
0
1
Homing error occurred, velocity is 0.
1
X
Reserved.
0x3003
Homing source object
Sub-index 0
Access: RO
Range: N/A
Size: 1 byte
Unit: N/A
Default: 2
Type:
USINT
Description: The number of the last sub-index in this object.
Sub-index 1
Access: RW
Range: 1 to 6
Size: 1 byte
Unit: N/A
Default: 5
Type:
USINT
Description: The source of homing switch. This will specify the number of a drive digital input/output; the
selected DIO also needs to be configured as an input.
This value will be read when CiA402 homing operation mode is selected.
Sub-index 2
Access: RW
Range: 0 to 1
Size: 1 byte
Unit: N/A
Default: 0
Type:
USINT
Description: Freeze or marker source for homing; this value will be read when CiA402 homing operation mode is
selected. This will have a value as follows:
0 - Use the marker of the feedback source selected for position feedback (see object 0x3000)
1 - Use the F1 freeze of the selected feedback source (drive or numbered option module).
2 - Use the F2 freeze of the selected feedback source (drive or numbered option module).
Summary of Contents for SI-EtherCAT