![Emerson SI-EtherCAT User Manual Download Page 84](http://html.mh-extra.com/html/emerson/si-ethercat/si-ethercat_user-manual_103938084.webp)
84
SI-EtherCAT User Guide
Issue Number: 2
Table 9-5 Menu 2 parameters (Ethernet over EtherCAT Status)
Table 9-6 Menu 9 parameters (Resources)
Parameter
Range
Default
Access
Size
(Bits)
S.02.000
Parameter mm.00
0 to 65535
RW
16
S.02.006
EoE IP Address
0 to 4294967295
(000.000.000.000
to
255.255.255.255)
RO
32
S.02.007
EoE Subnet mask
0 to 4294967295
(000.000.000.000
to
255.255.255.255)
RO
32
S.02.008
EoE Default gateway
0 to 4294967295
(000.000.000.000
to
255.255.255.255)
RO
32
S.02.011
EoE Virtual MAC Address
0 to 2
48
– 1
(0 to
FFFFFFFFFFFF)
RO
64
Parameter
Range
Default
Access
Size (Bits)
S.09.000
Parameter mm.00
0 to 65535
RW
16
S.09.010
Pre-critical task % free
0 to 100
RO
8
S.09.011
Critical task % free
0 to 100
RO
8
S.09.012
Post-critical task % free
0 to 100
RO
8
S.09.020
Pre-critical task worst % free
0 to 100
RO
8
S.09.021
Critical task worst % free
0 to 100
RO
8
S.09.022
Post-critical task worst % free
0 to 100
RO
8
S.09.030
PCB Temperature
-128 to 127
RO
8