This will count the number of PDO accesses per second. For example, if there are two PDOs
configured in Sync Manager 2, and two PDOs configured in Sync Manager 3, and both Sync
Manager memory areas are written every 250 µs, this parameter will contain a value of
approximately 16000 (the value may fluctuate slightly because it is not updated synchronously with
the accesses).
This parameter is purely a mapping to Pr
mm.000
to allow Pr
mm.000
to be accessed using a CoE
object (in the Control Techniques scheme, mapped CoE object indices correspond to menu
numbers and sub-indices correspond to parameter numbers; since sub-index zero is already used
for another CoE purpose, this cannot be used to access parameter zero of any menu).
9.4.3
Menu 2 (Ethernet over EtherCAT Status)
This menu provides information on the Ethernet over EtherCAT configuration.
This parameter shows the EoE IP address of the SI-EtherCAT module assigned by the EtherCAT
master.
This parameter shows the EoE Subnet mask of the SI-EtherCAT module assigned by the EtherCAT
master.
S.01.002
PDO Accesses per second
Minimum
0
Maximum
65535
Default
0
Units
Type
16 bit volatile
Update Rate
Written every second
Display Format
None
Decimal Places
0
Coding
RO, ND, NC, PT, BU
S.01.004
Mapped Parameter xx.000
Minimum
0
Maximum
65535
Default
0
Units
Type
16 bit volatile
Update Rate
Display Format
None
Decimal Places
0
Coding
RW, ND, NC, PT, BU
S.02.006
EoE IP Address
Minimum
0
(Display: 000.000.000.000)
Maximum
4294967295
(Display: 255.255.255.255)
Default
None
Units
Type
32 bit volatile
Update Rate
On EtherCAT Initialization
Display Format
IP
Decimal Places
0
Coding
RO, ND, NC, PT, BU
S.02.007
EoE Subnet Mask
Minimum
0
(Display: 000.000.000.000)
Maximum
4294967295
(Display: 255.255.255.255)
Default
None
Units
Type
32 bit volatile
Update Rate
On EtherCAT Initialization
Display Format
IP
Decimal Places
0
Coding
RO, ND, NC, PT, BU