4
Specifications
4.1
General specifications
Detected gases
•
Hydrogen sulfide (H
2
S)
•
Ammonia (NH
3
)
Table 4-1: Detection Distance Range
Detector
Source
Minimum installation
distance
Maximum installation
distance
H
2
S
RT126XXXX
T1T00XXXX
17 ft. (5 m)
52 ft. (16 m)
RT126XXXX
T2T00XXXX
46 ft. (14 m)
132 ft. (40 m)
RT126XXXX
T3T00XXXX
115 ft. (35 m)
200 ft. (60 m)
NH
3
R1T127XXXX
T1T00XXXX
17 ft. (5 m)
52 ft. (16 m)
R1T127XXXX
T2T00XXXX
46 ft. (14 m)
132 ft. (40 m)
R1T127XXXX
T3T00XXXX
115 ft. (35 m)
200 ft. (60 m)
Response time
< 3 sec, < 10 sec to T90
Spectral response
200 to 300 nm
Sensitivity range
Full scale
Warning
Alarm
500 ppm/m
100 ppm/m
300 ppm/m
Field of view
Line of sight
Alignment tolerance
±1 degree
Minimum detectable gas volume
50 ppm/m
Reference Manual
Specifications
00809-0100-4036
October 2021
Rosemount 936
25
Summary of Contents for Rosemount 936
Page 4: ...4 ...
Page 8: ...Product overview Reference Manual October 2021 00809 0100 4036 8 Emerson com Rosemount ...
Page 24: ...Operating modes Reference Manual October 2021 00809 0100 4036 24 Emerson com Rosemount ...
Page 30: ...Specifications Reference Manual October 2021 00809 0100 4036 30 Emerson com Rosemount ...
Page 50: ...Installation Reference Manual October 2021 00809 0100 4036 50 Emerson com Rosemount ...
Page 68: ...Wiring configurations Reference Manual October 2021 00809 0100 4036 68 Emerson com Rosemount ...
Page 72: ...Support Reference Manual October 2021 00809 0100 4036 72 Emerson com Rosemount ...
Page 74: ...Short range model Reference Manual October 2021 00809 0100 4036 74 Emerson com Rosemount ...