Quick Installation Guide
00825-0100-4750, Rev BB
January 2013
Rosemount 8750WA
24
8750WA12E Power Supply
For AC power applications (90-250 VAC, 50-60 Hz), connect AC Neutral to terminal N and
connect AC Line to terminal L1. For DC power applications, connect negative to terminal N
(DC -) and positive to terminal L1 (DC +). Ground the transmitter cage via the grounding
stud located on the bottom of the transmitter housing. Units powered by 12-42 V DC power
supply may draw up to 1 amp of current. See Figure 23 for terminal block connections.
Cover Jam Screw (8750WA32ES Only)
For transmitter housings shipped with a cover jam screw, the screw should be properly
installed once the transmitter has been wired and powered up. Follow these steps to install
the cover jam screw:
1. Verify that the cover jam screw is completely threaded into the housing.
2. Install the transmitter housing cover and verify that the cover is tight against the housing.
3. Using an M4 hex wrench, loosen the jam screw until it contacts the transmitter cover.
4. Turn the jam screw an additional
1
/
2
turn counterclockwise to secure the cover.
(Note: Application of excessive torque may strip the threads.)
5. Verify that the cover cannot be removed.
Figure 23. 8750WA12E Transmitter Power Connections
Transmitter
Power Cable
AC Neutral or DC–
AC Line or DC+
AC Ground or
DC Ground
Fuse
4750RevBBQIG.fm Page 24 Friday, January 11, 2013 6:26 PM