10
Reference Manual
00809-0200-4705, Rev AB
Configuration
May 2017
Configuration
If a custom volume unit is desired, the Rosemount 705 Transmitter can be configured to report the
totalized pulses, and a custom conversion can be done on the host system side. Similarly, if a custom flow
rate unit is desired, the transmitter can be configured to report pulses per second (Hertz), and a custom
conversion can be done on the host system side. When reporting pulses or hertz, the configured K-factor
has no affect on the reported values.
2.5
Joining the device to a network
To communicate with the Gateway, and ultimately the Host System, the transmitter must be configured
to communicate with the wireless network.
Using a Field Communicator or AMS Device Manager, enter the Network ID and Join Key so they match
the Network ID and Join Key of the Gateway and the other devices in the network. If the Network ID and
Join Key are not identical, the transmitter will not communicate with the network. The Network ID and
Join Key may be obtained from the Gateway on the
Network>Settings
page on the web server or by
clicking network information in the upper right hand corner. Using a Field Communicator, the Network
ID and Join Key can be configured using a Field Communicator with the Fast Key Sequence:
2, 1, 3
.
The final device network configuration piece is the update rate which, by default, is one minute. It can be
changed at commissioning, or at any time, by using AMS Device Manager or the Gateway’s web server.
The update rate should be between one second and 60 minutes. To change the update rate with a Field
Communicator, use the Fast Key sequence:
2, 1, 4
.
If doing a bench top initial configuration, after completion remove the power module until installation.
When the device is installed, insert the power module and close the housing cover securely. Always
ensure a proper seal so metal touches metal, but do not over tighten.
Units
Fast key
Volume
2, 1, 2
Flow
2, 2, 1
Summary of Contents for Rosemount 705
Page 2: ......
Page 6: ...vi Reference Manual 00809 0200 4705 Rev AB Contents May 2017 Contents ...
Page 10: ...2 Reference Manual 00809 0200 4705 Rev AB Introduction May 2017 Introduction ...
Page 32: ...28 Reference Manual 00809 0200 4705 Rev AB Commissioning May 2017 Commissioning ...
Page 69: ......