Table C-6: Empty Tank Handling
Parameter
Description
Empty tank detection area
The Empty Tank Detection Area defines a range
where it is accepted to lose the echo from the
product. If the echo is lost in this range, the tank
is considered empty and the level is presented
as 0.
When the tank is empty, the transmitter looks in
this range for the product surface. When a new
echo is found in this range, it is considered to be
the product surface. Therefore, if there are
disturbance echoes in this area, they may need
to be filtered out.
This function requires the Bottom echo visible
when tank is empty parameter to be disabled.
Bottom echo visible when tank is empty
Only enable this parameter if the bottom echo is
visible when tank is empty. By setting this
parameter, the bottom echo will be treated as a
disturbance echo to facilitate tracking of weak
surface echoes close to the tank bottom.
Related information
Enable bottom echo visible when tank is empty
Tank bottom projection
The Tank Bottom Projection is used to enhance measurement performance near the
bottom of the tank. When the tank bottom echo is strong (typical for flat tank bottoms)
and the dielectric constant of the product is low (e.g. oil), the transmitter may lock on the
bottom echo and report a false level measurement (empty tank). This problem can be
solved by using the Tank Bottom Projection function.
Table C-7: Tank Bottom Projection
Parameter
Description
Bottom product dielectric constant
Enter the product dielectric constant for the
product in the bottom of the tank.
Maximum projection distance
This defines the range where the function is
active. Enter the maximum distance from the
zero level (tank bottom).
Minimum tank bottom amplitude
Enter the minimum allowed amplitude for the
echo from the tank bottom before this function
is activated.
Related information
Configuration parameters
Reference Manual
February 2020
00809-0100-4408
268
Reference Manual
Summary of Contents for Rosemount 5408
Page 4: ...4 ...
Page 8: ...Contents Reference Manual February 2020 00809 0100 4408 viii Reference Manual ...
Page 10: ...Introduction Reference Manual February 2020 00809 0100 4408 10 Reference Manual ...
Page 20: ...Transmitter overview Reference Manual February 2020 00809 0100 4408 20 Reference Manual ...
Page 72: ...Mechanical installation Reference Manual February 2020 00809 0100 4408 72 Reference Manual ...
Page 100: ...Operation Reference Manual February 2020 00809 0100 4408 100 Reference Manual ...
Page 240: ...Product certifications Reference Manual February 2020 00809 0100 4408 240 Reference Manual ...
Page 242: ...Product certifications Reference Manual February 2020 00809 0100 4408 242 Reference Manual ...
Page 244: ...Product certifications Reference Manual February 2020 00809 0100 4408 244 Reference Manual ...
Page 246: ...Product certifications Reference Manual February 2020 00809 0100 4408 246 Reference Manual ...
Page 248: ...Product certifications Reference Manual February 2020 00809 0100 4408 248 Reference Manual ...