![Emerson Rosemount 5408 Reference Manual Download Page 200](http://html.mh-extra.com/html/emerson/rosemount-5408/rosemount-5408_reference-manual_103670200.webp)
Table A-18: Rosemount 5408 Series Spare Parts List - Antenna
(continued)
Dye penetration test certificate
Q73
Certificate of Liquid Penetrant Inspection
Positive material identification certificate
Q76
Positive Material Identification Certificate of Conformance
SBS
American Bureau of Shipping Type Approval
SDN
Det Norske Veritas Germanischer Lloyd (DNV GL) Type Approval
SLL
Lloyd's Register Type Approval
SBV
Bureau Veritas Type Approval
Extended product warranty
WR3
3-year Limited Warranty
WR5
5-year Limited Warranty
Specials (see
PXXXX
Custom Engineered Solutions beyond standard model codes. Consult factory for details.
Typical model number: 5408 Z 9 Z Z Z Z NA 1 R 3 AB CAB 3
(1)
Type A flat face for EN 1092-1 flanges.
(2)
Type B1 raised face for EN 1092-1 flanges.
(3)
For applications where saturated steam may occur, consult factory.
(4)
Pressure limit is derated for process temperatures above 100 °F (38 °C), see
for details.
(5)
Refer to
for pressure/temperature ratings of Tri-Clamp connection.
(6)
1
½
-in. (DN40) cone antenna is available for 1
½
-in. NPT threaded connection and materials of construction code 1
(316/316L/EN 1.4404).
(7)
Option code PC1 is for cone antennas only, and requires matching flange and antenna sizes. Note that all parabolic
antennas come with an integrated air purge connection.
(8)
A minimum gasket thickness of 0.125 in. (3.2 mm) is required for flanges with protective plate design.
(9)
Only applies to flanged process connections with welded construction or protective plate design; only applicable to
cone antennas (see
and
).
(10)
Flanged process connections with protective plate design are only available with ASME IX (option code AW).
(11)
Not available with EN1092-1 or JIS B2220 flanges, neither for ASME B16.5 flanges in materials of construction code M.
(12)
Hydrostatic testing is only available for cone antennas and process seal antennas with flanged process connections.
(13)
Certificate includes all pressure retaining and wetted parts.
(14)
Only available for process seal antennas with Tri-Clamp connection.
(15)
Applicable only to wetted parts.
(16)
Not available with parabolic antenna.
(17)
Transmitters with aluminum housing are not approved for open deck installations; for use only in engine room, pump
room, etc.
A.6.1
Accessories
Table A-19: Accessories
HART modem and cable
03300-7004-0002 MACTek
®
VIATOR
®
HART modem and cables (USB connection)
Specifications and reference data
Reference Manual
February 2020
00809-0100-4408
200
Reference Manual
Summary of Contents for Rosemount 5408
Page 4: ...4 ...
Page 8: ...Contents Reference Manual February 2020 00809 0100 4408 viii Reference Manual ...
Page 10: ...Introduction Reference Manual February 2020 00809 0100 4408 10 Reference Manual ...
Page 20: ...Transmitter overview Reference Manual February 2020 00809 0100 4408 20 Reference Manual ...
Page 72: ...Mechanical installation Reference Manual February 2020 00809 0100 4408 72 Reference Manual ...
Page 100: ...Operation Reference Manual February 2020 00809 0100 4408 100 Reference Manual ...
Page 240: ...Product certifications Reference Manual February 2020 00809 0100 4408 240 Reference Manual ...
Page 242: ...Product certifications Reference Manual February 2020 00809 0100 4408 242 Reference Manual ...
Page 244: ...Product certifications Reference Manual February 2020 00809 0100 4408 244 Reference Manual ...
Page 246: ...Product certifications Reference Manual February 2020 00809 0100 4408 246 Reference Manual ...
Page 248: ...Product certifications Reference Manual February 2020 00809 0100 4408 248 Reference Manual ...