96
Reference Manual
00809-0100-4102, Rev AA
Appendix A: Reference Data
June 2012
Specifications and Reference Data
Table A-7. Rosemount 2051L Liquid Level Transmitter Ordering Information
★
The Standard offering represents the most common options. The starred options (
★
) should be selected for best delivery.
__
The Expanded offering is subject to additional delivery lead time.
Model
Transmitter Type
2051L
Liquid Level Transmitter
Pressure Range
Standard
Standard
2
–250 to 250 inH
2
O (–0,6 to 0,6 bar)
★
3
–1000 to 1000 inH
2
O (–2,5 to 2,5 bar)
★
4
–300 to 300 psi (–20,7 to 20,7 bar)
★
Transmitter Output
Standard
Standard
A
4–20 mA with Digital Signal Based on
HART
Protocol
★
F
F
OUNDATION
fieldbus Protocol
★
W
(1)
Profibus PA Protocol
★
X
Wireless
★
Expanded
M
Low-Power 1–5 V dc with Digital Signal Based on
HART
Protocol
(See Option Code C2 for 0.8–3.2 V dc Output)
Process Connection Size, Material, Extension length (High Side)
Standard
Standard
Code
Process Connection Size
Material
Extension Length
★
G0
(2)
2-in./DN 50
316L SST
Flush Mount Only
★
H0
2-in./DN 50
Alloy C-276
Flush Mount Only
★
J0
2-in./DN 50
Tantalum
Flush Mount Only
★
A0
3-in./DN 80
316L SST
Flush Mount
★
A2
3-in./DN 80
316L SST
2-in./50 mm
★
A4
3-in./DN 80
316L SST
4-in./100 mm
★
A6
3-in./DN 80
316L SST
6-in./150 mm
★
4-in./DN 100
316L SST
Flush Mount
★
4-in./DN 100
316L SST
2-in./50 mm
★
4-in./DN 100
316L SST
4-in./100 mm
★
4-in./DN 100
316L SST
6-in./150 mm
★
C0
3-in./DN 80
Alloy C-276
Flush Mount
★
C2
3-in./DN 80
Alloy C-276
2-in./50 mm
★
C4
3-in./DN 80
Alloy C-276
4-in./100 mm
★
C6
3-in./DN 80
Alloy C-276
6-in./150 mm
★
D0
4-in./DN 100
Alloy C-276
Flush Mount
★
D2
4-in./DN 100
Alloy C-276
2-in./50 mm
★
D4
4-in./DN 100
Alloy C-276
4-in./100 mm
★
D6
4-in./DN 100
Alloy C-276
6-in./150 mm
★
E0
3-in./DN 80
Tantalum
Flush Mount Only
★
F0
4-in./DN 100
Tantalum
Flush Mount Only
★
Mounting Flange Size, Rating, Material (High Side)
Size
Rating
Material
Standard
Standard
M
2-in.
ANSI/ASME B16.5 Class 150
CS
★
A
3-in.
ANSI/ASME B16.5 Class 150
CS
★
B
4-in.
ANSI/ASME B16.5 Class 150
CS
★
Summary of Contents for Rosemount 2051 Wireless Series
Page 2: ......
Page 12: ...4 Reference Manual 00809 0100 4102 Rev AA Section 1 Introduction June 2012 Introduction ...
Page 32: ...24 Reference Manual 00809 0100 4102 Rev AA Section 2 Configuration June 2012 Configuration ...
Page 110: ......
Page 113: ......
Page 117: ...iv Reference Manual 00809 0100 4100 Rev AA Title Page June 2012 ...
Page 123: ...x Reference Manual 00809 0100 4100 Rev AA Table of Contents June 2012 Table of Contents ...
Page 167: ...44 Reference Manual 00809 0100 4100 Rev AA Section 3 Installation June 2012 Installation ...
Page 168: ...45 Reference Manual 00809 0100 4100 Rev AA Section 3 Installation June 2012 Installation ...
Page 169: ...46 Reference Manual 00809 0100 4100 Rev AA Section 3 Installation June 2012 Installation ...
Page 249: ......