3-WAY WIRlNG DIAGRAM:
NEW CONSTRUCTION
6.
Screw wall control into wall box using
the supplied screws. Leave wall
control in “OFF” mode until fan
installation is completed.
7.
The wall control is supplied with a
white, ivory, and almond color switch
covers. Choose the finish that best
suits your needs and snap the cover
onto the wall control (Figure 7).
8.
Next, install the other wall control into
the wall box containing the load wire.
Connect the black wire of the wall
control to the traveler wire(s) already
connected to the black wire (in the
other wall box). Secure with wire
connectors supplied.
9.
Connect one black wire of the wall
control to the “load” (black) wire and
secure with wire connector supplied.
Check to see that all connections are tight
and that no bare wires are visible at the
wire connectors.
!
WARNING
HOT
BLACK
SW605
FAN/LIGHT
WALL
CONTROL
TRAVELER
WIRE
BLK
BLK LOAD
BLACK
GROUND
NEUTRAL
RECEIVER LOCATED
WITHIN THE CEILING
COVER
EMERSON
®
EMERSON
®
HI
MED
LOW
FAN OFF
LIGHT
ON
OFF
HI
MED
LOW
FAN OFF
LIGHT
ON
OFF
Figure 8
HOT
BLK
TRAVELER WIRES
BLACK
LOAD
EXISTING
WALL CONTROL
FAN/LIGHT
WALL CONTROL
BLK
BLACK
LOAD
TRAVELER WIRES
HOT
BLK
EMERSON
®
EMERSON
®
BLK
BLK
HI
MED
LOW
FAN OFF
LIGHT
ON
OFF
HI
MED
LOW
FAN OFF
LIGHT
ON
OFF
3-WAY WIRING DIAGRAM: RETROFIT
Figure 9
Operation of Your Wall
Control
(Figure 10)
Your wall control has full control of your
fan and light.
NOTE: Prior to operation of the fan and
light from the wall control, set the fan
speed to HIGH (....) and turn the light
ON ( ).
1.
To set the desired fan speed, press the
( ) button to decrease the speed and
the ( ) to increase the speed. The LED
display will light up to indicate the new
speed selected.
2.
To turn the light on and off, press and
release the LIGHT ( ) button. To set
the light intensity, press and hold the
LIGHT ( ) button. The light will turn on
at the light intensity previously selected.
3.
Your wall control comes complete with
your choice of three wall cover plates;
ivory, white and light almond.
Fan installation must be completed,
including the installation of the fan
blades, before testing the remote control.
IMPORTANT
STANDARD WIRING FOR EXISTING
3-WAY CONTROLS
8
BP7415 RC188 & RC212 Receiver 10/30/09 11:29 AM Page 8