Figure 5
Setting Operating
Frequency of SW605
Wall Control
Your wall control has code switches which
must be set in one of 32 possible code
combinations (Figure 5). The five levers
(numbered 1, 2, 3, 4, and 5) on the
switches are factory-set in the ON (up)
position. Change the switch settings as
follows:
1.
Slide the five switch levers in the wall
control to your choice of ON (up) or
down positions. Use a ball-point pen or
small screwdriver and slide the levers
firmly up or down.
2.
When power is restored after
installation of the wall control, push and
hold the fan OFF button ( ) for
3 to 5 seconds to set the code in the
receiver.
3.
The sixth switch marked ON and I is for
dimming control of lights: Set switch to
ON to allow for dimming of the lights.
Set switch to I for no dimming of the
lights such as for fluorescent bulbs.
WALL CONTROL
CODE SWITCHES
ON
1
2
3
4 5
I
CODE
SWITCHES
WALL
CONTROL
Installation of Wall Control
SINGLE-POLE INSTALLATION
(Figure 6)
1.
Disconnect electrical power to the
branch circuit at the circuit breaker or
fuse box before attempting to install the
ceiling fan wall control into the outlet box.
2.
Remove faceplate and screws from
existing wall control. Pull control out
from the wall box. Determine the “hot”
wire and the “load” wire and disconnect
these wires from control. Do not
attempt to disconnect any wires not
already connected to existing control.
3.
Before installing wall control, place wall
control in “OFF” mode by pushing
“ON/OFF” switch to the “OFF” position.
EMERSON
®
HI
MED
LOW
FAN OFF
LIGHT
ON
OFF
SW605 FAN/LIGHT
WALL CONTROL
HOT
BLK
NEUTRAL
BLACK
GROUND
LOAD
BLACK
RECEIVER LOCATED
WITHIN THE CEILING
COVER
Figure 6
Turning off wall switch is not sufficient.
To avoid possible electrical shock, be
sure electricity is turned off at the main
fuse or circuit breaker box before wiring.
All wiring must be in accordance with
National and Local codes and the ceiling
fan must be properly grounded as a
precaution against possible electrical
shock.
!
WARNING
CAUTION: To reduce the risk of
electrical shock, disconnect the
electrical supply circuit before
installing the fan, light kit or receiver.
NOTE: Make all wiring connections
using wire connectors (supplied). Make
sure that all connections are tight,
including ground, and that no bare wire
is visible at the wire connectors, except
for the ground wire.
6
SECTION TWO:
BP7415 RC188 & RC212 Receiver 10/30/09 11:29 AM Page 6