18
ETL Model No.: CF965
7. Optional AL100 Accent Light Installation
7.2
CAUTION: To reduce the risk of electric shock,
disconnect the electrical supply circuit to the fan
before installing light kit assembly.
Position the AL100 accent light so that the opening of the
AL100 accent light slides through the downrod. Align the
mounting holes of the AL100 accent light to the motor
assembly (Figure 29).
NOTE: Be sure the AL100 accent light connector is
located close to the motor assembly connector for
ease of installation.
Install the AL100 accent light to the motor assembly using
three AL100 accent light mounting screws
previously removed on Step 7.1.
LOWER
HOUSING
SCREWS (4)
AL100 ACCENT
LIGHT HARNESS
AL100 ACCENT
LIGHT HARNESS
CONNECTOR
FAN MOTOR ACCENT
LIGHT CONNECTOR
Figure 29
7.3
Securely connect the AL100 accent light connector to the
motor assembly connector (Figure 30).
Screw the four 25-watt candelabra base bulbs into the
AL100 accent light sockets (Figure 30).
25-WATT CANDELABRA
BASE BULBS (4)
AL100 ACCENT
LIGHT SOCKETS (4)
LIGHT KIT & FAN MOTOR
ACCENT LIGHT CONNECTORS
Figure 30
CAUTION: To reduce the risk of electrical shock,
disconnect the electrical supply circuit before
installing the accent light kit.
7.1
Loosen and remove all three pre-installed AL100 mounting
screws from the upper housing of the motor assembly
(Figure 28). Retain the screws for re-installation.
LOWER HOUSING
SCREWS (4)
GLASS
SHADE
Figure 28
Turning off wall switch is not sufficient. To avoid possible
electrical shock, be sure electricity is turned off at the main
fuse or circuit breaker box before wiring. All wiring must be
in accordance with National and Local codes and the
ceiling fan must be properly grounded as a precaution
against possible electrical shock.
WARNING
!
Return to Section 3.17 and complete the
remaining installation instructions.
Summary of Contents for Portland CF965BS00