background image

1. Open styrofoam unit containing fan. Remove upper

and center sections of styrofoam unit. Remove parts
and check to see that you have received the following:

a. One fan motor and housing assembly
b. One motor coupling cover
c. One ceiling cover
d. Five fan blades
e. Five blade holder caps (left)
f. Five blade holder caps (right)
g. One hanger ball/downrod assembly
h. One hanger bracket
i. One light kit adapter assembly
j. One light kit plate assembly
k. One light kit glass 
l. Two die cast light kit glass holders
m.One uplight lead assembly 
n. One loose parts bag containing:

1. One setscrew
2. One 5/32" hex wrench
3. One 3/16” hex wrench
4. Four 8-32 x 1-1/4” threaded studs
5. Four knurled knobs
6. Four lockwashers
7. Seven wire connectors
8. Three 8-32 x 3/8" phillips head screws
9. One hairpin clip

10. One clevis pin
11. Twenty-one 10-32 x 3/8" pan head screws
12. One flatwasher

This Manual Is Designed to Make it as Easy as Possible for You to

Assemble, Install, Operate and Maintain Your Ceiling Fan

Tools Needed for Assembly

One six-inch blade screwdriver

One stepladder

One Phillips head screwdriver

One wire stripper

Seven wire connectors(supplied.) 

MATERIALS

Wiring outlet box and box connectors must be of type
required by the local code. The minimum wire would
be a 3-conductor (2-wire with ground) of the wire size,
to right:

3

Installed Wire Length

Wire Size A.W.G.

Up to 50 ft.

14

50-100 ft.

12

Unpacking Instructions

For your convenience, check-off boxes are provided next to each step. As each step is completed, place a
check mark in the box. This will insure that all steps have been completed and will be helpful in finding
your place should you be interrupted.

BLADE HOLDER
CAPS (LEFT)

BLADE HOLDER
CAPS (RIGHT)

UPPER STYROFOAM
SECTION

CEILING
COVER

FAN BLADES

MOTOR
COUPLING
COVER

HANGER BALL/
DOWNROD
ASSEMBLY

HANGER 
BRACKET

LOOSE
PARTS
BAG

CENTER
STYROFOAM
SECTION

LIGHT KIT
PLATE
ASSEMBLY

LIGHT KIT
GLASS 

LIGHT KIT
ADAPTER
ASSEMBLY

LOWER 
STYROFOAM
SECTION

FAN MOTOR
AND HOUSING
ASSEMBLY

UPLIGHT
LEAD ASSEMBLY

DIE CAST
GLASS HOLDERS

If you feel you do not have enough wiring knowledge or
experience, have your fan installed by a licensed
electrician.

NOTE: Place the parts from the loose parts bags
in small containers to keep them from being lost.
If any parts are missing, contact your local
retailer or catalog outlet for replacement before
proceeding.

Do not install or use fan if any part is damaged or
missing. Call Toll-Free:

1-800-654-3545

This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Company. Substitution of parts or acces-
sories not designated for use with this product by
Emerson Company could result in personal injury or
property damage.

WARNING

!

WARNING

!

WARNING

!

Summary of Contents for ODYSSEY CF2454BQ02

Page 1: ...READ AND SAVE THESE INSTRUCTIONS Model No CF2454WW02 CF2454BS02 CF2454PW02 CF2454BQ02 THE ODYSSEY Series Ceiling Fan Owner s Manual Part No F40BP72110008 Form No BP7211 8 Net Weight 26 0 Lbs ...

Page 2: ...rician 3 The outlet box and joist must be securely mounted an capable of reliably supporting a least 50 pounds Use only U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt ...

Page 3: ...of the wire size to right 3 Installed Wire Length Wire Size A W G Up to 50 ft 14 50 100 ft 12 Unpacking Instructions For your convenience check off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted BLADE HOLDER CAPS LEFT BLADE HOLDER CAP...

Page 4: ...L DOWNROD CLEVIS PIN SETSCREW Figure 2 4 DOWNROD CUT HERE 3 UPLIGHT YELLOW LEAD ASSEMBLY WIRING HARNESS BLUE WIRE Figure 3 IF THE CF2454 CEILING FAN IS BEING INSTALLED WITH ANY OTHER CONTROL METHOD SKIP SECTION A AND GO TO SECTION B TO BEGIN ASSEMBLY INSTRUCTIONS Electrical Requirements If your fan is to replace an existing ceiling light fixture turn electricity off at the main fuse box at this ti...

Page 5: ...ng All wires and wire connectors should be placed through the motor coupling slot beneath the down rod See Figure 5 7 Align the clevis pin holes in the downrod with the holes in the motor coupling Install the clevis pin and secure with the hairpin clip The clevis pin must go through the holes in the motor coupling and the holes in the downrod Figure 5 Push the straight leg of the hairpin clip thro...

Page 6: ...e downrod and slide the hanger ball up the downrod aligning the ball so the pin is cap tured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble 12 Position the center styrofoam section on the upper section and then position the fan motor and housing on the center sec...

Page 7: ...ntrol by passing the opening in the receiver over the downrod Figure 17 The fan must be hung with at least 7 of clearance from floor to blades Figure 14 WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked acceptable for fan support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable...

Page 8: ...assembly and remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod Figure 18 Remove the pin from the downrod then remove the hanger ball Retain the pin and hanger ball for reinstallation in step 9 4 Push the uplight yellow lead assembly connector through the downrod Figure 19 until it extends about 4 5 Cut the yellow lead approximately 3 f...

Page 9: ...inst the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble 13 The blue black yellow and white leads exiting the downrod are 80 inches long Before installing fan measure up approximately 6 to 9 inches above the ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads NOTE If you are installing your fan with a SR3...

Page 10: ...lips head screws supplied into the threaded holes in the adapter assembly Figure 27 NOTE Do not pinch wires between the light kit plate assembly and the adapter assembly 19 Lift the fan assembly from the styrofoam and remove the center styrofoam section Turn the fan assembly over and carefully position it on the upper styrofoam section so that the hanger ball downrod assembly is at the top Figure ...

Page 11: ...lack wire from the downrod to the supply black hot wire using wire connector supplied c Cut terminal off of the yellow lead wire and strip insulation 1 2 from end of wire d Securely connect the blue wire and yellow wire from the downrod to the supply red hot wire using wire connector supplied After connec tions have been made turn leads upward and carefully push leads into the outlet box with the ...

Page 12: ...BOX LIGHT CONTROL GREEN WIRE GROUND FROM HANGER BRACKET TO 120 VOLT SUPPLY WHITE WHITE GROUND GROUND GREEN WIRE GROUND FROM HANGER BALL LISTED WIRE CONNECTOR 4 GROUND WIRE WHT RED BLACK EMERSON FAN CONTROL BLACK HOT YELLOW BLUE RED FINAL ASSEMBLY 1 Screw the two 1 1 4 threaded studs supplied into the tapped holes in the hanger bracket 2 Lift the ceiling cover up to the threaded studs and turn unti...

Page 13: ... operating 2 Screws holding blades to flange assemblies 2 Tighten screws securely are loose 3 Fan wobbles 1 Setscrew in motor coupling is loose 1 Raise motor cover and tighten setscrew excessively securely 2 Setscrew in hanger ball downrod assembly 2 Tighten the setscrew in the hanger ball is loose downrod assembly 3 Hanger bracket and or ceiling outlet box is not 3 Tighten the hanger bracket scre...

Page 14: ...14 20 12 13 14 4 2 1 3 5 6 7 9 10 17 16 24 21 3 8 11 19 22 26 25 23 8 18 17 15 15 7 27 Repair Parts ...

Page 15: ...802 6 21 Light Kit Plate Assembly 761810 761810 761810 761810 22 Light Kit Glass 761745 761745 761745 761745 23 Die Cast Glass Holder 761864 3 761864 761864 5 761864 6 26 Uplight Lead Assembly 761790 761790 761790 761790 Loose Parts Bag containing 761798 2 761798 761798 1 761798 1 3 Threaded Stud 8 32 x 1 1 4 4 5 Wire Connector 7 6 Setscrew Wrench 5 32 7 Lockwasher 4 8 Knurled Knob 4 11 Clip Hairp...

Page 16: ...e responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover a...

Reviews: