17
emersonfans.com
Please contact 1-800-654-3545 for further assistance
ETL Model No.: CF860
8. Light Kit Assembly Replacement
8.1
METHOD 1- REPLACING THE ENTIRE LIGHT
KIT ASSEMBLY.
8.2
Rotate and remove the shade counter-clockwise to
expose the Light Kit Assembly (Figure 30).
Retain shade for future use.
LIGHT KIT
ADAPTER
RAISED
DIMPLES (3)
SHADE
FLAT AREA OF
SHADE (3)
ROTATE COUNTER-
CLOCKWISE
Figure 30
8.3
Loosened the two Light Kit Adapter #6-32 x .375” pan
head screws located in the key hole slots.
Remove the remaining Light Kit Adapter #6-32 x .375”
pan head screw (Figure 31). Retain for future use.
Rotate the Light Kit Assembly clockwise to disengage
the two screw heads in the key hole slots for removal of
Light Kit Assembly.
LOOSEN LIGHT KIT ADAPTER
PAN HEAD SCREWS (2)
LIGHT KIT
ASSEMBLY
LIGHT KIT ADAPTER PAN
HEAD SCREW (1)
ROTATE CLOCKWISE
Figure 31
Repair of the Light Kit can be Accomplished By; 1) Replacing the Entire Light Kit Assembly
or; 2) Replacing the Driver or Array Components Individually.
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse box before wiring. All wiring must
be in accordance with National and Local codes and
the ceiling fan must be properly grounded as a
precaution against possible electrical shock.
WARNING
!
To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is grounded,
contact a licensed electrician for advice, as it must be
grounded for safe operation.
WARNING
!
BP7515 CF860 Luray Eco 1/4/16 2:35 PM Page 17