1592022020 iCHILL 100D EVO QRG EN rel. 2.0 23.02.2022                                

 

27/40

 

VTIC10 TOUCH PANEL (WALL MOUNTING) 
 

 

 

 

17.2 

A

NALOG 

I

NPUTS 

NTC

 

 

PTC

 

P

ROBES

 

PbC

 = common terminal 

Pb1…Pb6

 = probe inputs 

 

Summary of Contents for Lumity IC100D EVO

Page 1: ...QUICK REFERENCE GUIDE IC100D EVO rel 2 0 ...

Page 2: ......

Page 3: ...LREADY PROGRAMMED HOT KEY DOWNLOAD 13 9 2 HOW TO COPY THE PARAMETER MAP INTO THE HOT KEY UPLOAD 13 10 PROGRAMMING USING LOCAL USER INTERFACE 13 10 1 ENTER PARAMETERS PROGRAMMING LEVEL PR1 14 10 2 ENTER PARAMETERS PROGRAMMING LEVEL PR2 14 10 3 ENTER PARAMETERS PROGRAMMING LEVEL PR3 14 11 MENU MENU KEY 15 11 1 ALARM LIST READ AND RESET 15 11 2 ALARM LOG LIST 16 12 REMOTE KEYBOARD VI613 16 13 REMOTE ...

Page 4: ...ER CONTROLLED OR FOR AUXILIARY OUTPUTS 31 17 8 PROPORTIONAL OUTPUT 0 10V TO CONTROL DUMPER MOTORS 32 17 9 PROPORTIONAL OUTPUTS CONFIGURED FOR AUX RELAY CONTROL 34 17 10 CONNECTION TO THE IEV22D OR IEV12D ELECTRONIC EXPANSION VALVE DRIVER 35 18 INSTALLING AND MOUNTING 36 18 1 MECHANICAL CHARACTERISTIC 36 18 2 VERTICAL BOARDS VI613 PANEL CUT OUT 37 19 ELECTRICAL CONNECTIONS 38 20 TECHNICAL DATA 38 2...

Page 5: ...t back to the distributor or to Dixell S r l with a detailed description of the fault Consider the maximum current which can be applied to each relay see Technical Data Ensure that the wires for probes loads and the power supply are separated and far enough from each other without crossing or intertwining do not use the same electrical conduit to install high voltage cabling and low voltage cablin...

Page 6: ...he goods in accordance with local laws Furthermore at the end of the product s life it is also possible to return this to the retailer when a new purchase is made This equipment may contain hazardous substances Improper use or incorrect disposal can have adverse effects on human health and the environment The symbol shown on the product or the package indicates that the product has been placed on ...

Page 7: ...TIONAL OUTPUTS 2 0 10V or 4 20mA or PWM outputs configurable configurable 1 0 10V configurable configurable OTHER OUTPUTS TTL serial line Modbus RTU protocol RS485 Modbus RTU protocol Remote panel VI613 up to 2 remote keyboards or one V2I810 LCD panel or one VT810 Touch panel LAN to connect IEV electronic expansion valve driver POWER SUPPLY 12 Vac dc 15 10 24 Vac dc 10 opt opt OTHERS Internal real...

Page 8: ...NCTIONNING C F BAR PSI Lighted when the display shows a temperature or pressure Lighted when the bottom display shows the clock Lighted during the programming parameters if it is time based Lighted in function menu when the display shows the defrost delay Alarm blinking in case of alarm Lighted when sanitary hot water function is active ...

Page 9: ... Water pump lighted if at least one pump is ON Condenser fan lighted if at least one fan is ON Lighted when a compressor is ON Blinking when the delay of activation is running AUX Lighted when auxiliary function is active Lighted when the controller is ON in cooling or heating FC Lighted when the Free cooling is active Lighted when the defrost is activated Blinking when the delay to activate the d...

Page 10: ... case where the Energy Saving and or function dynamic set point are active press SET key again lower display shows SEtS set sanitary circuit in case it is enabled If the instrument is in chiller operation lower display shows SEtC set chiller press SET key again lower display shows SEtr set real of operation in the case where the Energy Saving and or function dynamic set point are active press SET ...

Page 11: ...g push once To enter parameter modification or confirm a value Push when an alarm is showed in menù ALrM To reset the alarm Push once To read probes value Pushing once during the programming To change the group of parameters to change the parameter to change the value of the parameter Push for 1 second during the programming when the display visualizes Pr1 or Pr2 or Pr3 1 time shows the Pr2 progra...

Page 12: ...the other levels 8 FIRST INSTALLING 8 1 ON BOARD CLOCK OPTIONAL In case of power failure the time and date are maintained for about 3 days at room temperature 25 C the display shows the message rtC and it is necessary to set the clock 8 2 RTC SETUP 1 Push Menu key continuously for 3 seconds until the bottom display shows Hour and the top display shows its value 2 Push SET one time the value is bli...

Page 13: ...tom display 5 Push SET key and immediately the instrument starts transfer the parameters into the Hot key During the upload the regulation is locked and the top display shows the UPL blinking label At the end of the UPLOAD will appear 1 End if the programming procedure is completely OK after 30seconds the regulation starts automatically 2 Err if the programming procedure has found an error and the...

Page 14: ...ey and the top display shows 0 blinking 4 Push UP or DOWN to select Pr2 password 5 Push SET and if the value is correct the top display shows the first family of parameters ALL 6 Push UP or DOWN to select the parameter family 7 Push SET to enter the bottom display shows the first available parameter label while the top display shows its value 8 Push UP or DOWN to modify its value 9 Push SET to con...

Page 15: ...utput Pout Read the percentage of the proportional output 0 10 Vdc PoEn Enable disable evaporator or condenser water pumps dF Time counting to next defrost cycle under heat pump mode uS Read the probe temperatures that enabled to control the auxiliary output SoL Read temperature Set point and output status of solar panel FC Read temperature Set point and output status of Free cooling trEM Read pro...

Page 16: ...lect ALOG 3 Push the SET key 4 Push UP or DOWN keys and search the ArSt label on the bottom display the top display shows PAS 5 Push SET the bottom display shows PAS and the top display shows 0 blinking 6 Push UP or DOWN to set the password 7 If the password is OK the label ArST blinks for 5 seconds then the display returns to normal condition read out 8 If the password is not correct the display ...

Page 17: ...3 02 2022 17 40 13 REMOTE LCD PANEL V2I810 The description of the user interface is available in the user manual of the Visograph 14 REMOTE TOUCH PANEL VTIC10 The description of the user interface is available in the user manual of the Visotouch ...

Page 18: ...Evaporator flow alarm OFF 4 OFF boiler 8 OFF 3 8 8 8 8 8 AEht High inlet evaporator water temperature OFF OFF boiler 8 8 8 8 8 8 8 AHFL Domestic hot water flow switch alarm OFF 6 8 8 8 OFF OFF 8 8 8 ALC1 General alarm OFF OFF OFF OFF OFF OFF OFF OFF ALC2 General alarm type 2 OFF 9 OFF 9 OFF 9 OFF 9 OFF 9 OFF 9 OFF 9 OFF 9 OFF 9 ALSF Phase sequence alarm OFF OFF OFF OFF OFF OFF OFF OFF OFF ALti Low...

Page 19: ...verload alarm OFF OFF OFF 8 8 AUAL Serial communication failure with IEV expansion valve driver OFF OFF OFF OFF OFF OFF OFF OFF AtrE Remote terminal Visograph 2 0 communication alarm 1 1 1 1 1 1 1 1 1 Atr1 Atr2 Remote terminal VI613 communication alarm 1 1 1 1 1 1 1 1 1 1 the status of the load depends on wich probe is faulty e g if the regulation probe is faulty main loads are OFF if external tem...

Page 20: ...e Alarm description Compressors Fan condensing b1AC Anti freeze alarm in chiller mode OFF OFF b1Ac Anti freeze warning in chiller b1AH Anti freeze alarm in heat pump OFF OFF b1Ah Anti freeze warning in heat pump b1dF End defrost alarm b1HP High pressure switch OFF OFF after 60 seconds b1hP High condenser pressure by pressure transducer OFF OFF after 60 seconds b1hP High condensing temperature OFF ...

Page 21: ... Condenser 2 water pump maintenance AEun Unloading by high evaporator inlet temperature ASAn Domestic hot water pump maintenance ASUn Solar panel water pump maintenance ArtC Clock to be set the device if not powered for some days loses the time and the date ArtF Clock failure C n Mn Compressor n maintenance b1Cu Unloading by high or low evaporator or condenser temperature or pressure b1Cu Unloadin...

Page 22: ...transducer ratio metric 0 5 0 Volt 4 modulating outputs 1 x 0 10 Volt 2 x 0 10 0 Volt or 4 20mA or PWM PWM only for condenser fan modulation 1 x output to connect a remote keyboard max 2 VI613 remote keyboards or 1 Visograph or 1 Visotouch 1 x LAN to connect the IEV electronic expansion valve driver max 1 IEV 1 x TTL output for HotKey 64 for parameters programming or for XJ485CX interface module f...

Page 23: ...analogue inputs 5 x NTC preobe PTC probe digital input 3 x NTC preobe PTC probe digital input pressure transducer 4 20 mA pressure transducer ratio metric 0 5 0 Volt 4 modulating outputs 1 x 0 10 Volt 2 x 0 10 0 Volt or 4 20mA or PWM PWM only for condenser fan modulation 1 x output to connect a remote keyboard max 2 VI613 remote keyboards or 1 Visograph or 1 Visotouch 1 x LAN to connect the IEV el...

Page 24: ...put for HotKey 64 for parameters programming or for XJ485CX interface module for monitoring system 1 x RS485 output to connect the device to a RS485 network monitoring system or XWEB system max current of relay contacts 5 2 A 250V max current of relay common line 10A 250V ...

Page 25: ...al VI613 is provided with probe on board the temperature adjustment can be performed with the probe of the terminal The connection of the remote terminals must be performed using a shielded twisted cable such as Belden 8772 wires 1 mm2 minimum the maximum length of VI613 terminal cable is 100 mt maximum length of the connection both if using one or two keyboards the maximum length of V2I810 or VTI...

Page 26: ...1592022020 iCHILL 100D EVO QRG EN rel 2 0 23 02 2022 26 40 V2I810 LCD PANEL PANEL MOUNTING VTIC10 TOUCH PANEL PANEL MOUNTING ...

Page 27: ...1592022020 iCHILL 100D EVO QRG EN rel 2 0 23 02 2022 27 40 VTIC10 TOUCH PANEL WALL MOUNTING 17 2 ANALOG INPUTS NTC PTC PROBES PbC common terminal Pb1 Pb6 probe inputs ...

Page 28: ...EN rel 2 0 23 02 2022 28 40 17 3 DIGITAL INPUTS GND common terminal ID1 ID11 digital inputs 17 4 ANALOG INPUT FOR PRESSURE TRANSDUCER PP30 4 20MA SIGNAL 12V power supply for pressure transducers Pb3 and Pb4 pressure transducer inputs ...

Page 29: ... EVO QRG EN rel 2 0 23 02 2022 29 40 17 5 ANALOG INPUT FOR PRESSURE RATIOMETRIC TRANSDUCER PPR30 0 5V SIGNAL 5V power supply for pressure transducers GND ground for pressure transducers Pb3 and Pb4 pressure transducer inputs ...

Page 30: ...OUTPUT FOR CONDENSING FAN SPEED CONTROL OUT2 and OUT3 signals for the modulation of the condenser fan GND ground for pressure transducers The compatible modules are the following XV05PK mono phase 500 Watt 2A XV10PK mono phase 1000 Watt 4A XV22PK mono phase 2200 Watt 9A ...

Page 31: ... rel 2 0 23 02 2022 31 40 17 7 PROPORTIONAL OUTPUT FOR FAN CONDENSING CONTROL OR FOR COMPRESSOR INVERTER CONTROLLED OR FOR AUXILIARY OUTPUTS OUT1 OUT3 signals for the modulation of the condenser fan GND ground for pressure transducers ...

Page 32: ...OUT4 signals for the modulation of the dumper motor GND ground If the dumper motor has a common line between a pole of the power supply and the pole of the 0 10V signal it is necessary to use two transformers for the power supply of the controller Ichill and the power supply of the dumper motor 0 10V Command signal input ...

Page 33: ...1592022020 iCHILL 100D EVO QRG EN rel 2 0 23 02 2022 33 40 ...

Page 34: ...1592022020 iCHILL 100D EVO QRG EN rel 2 0 23 02 2022 34 40 17 9 PROPORTIONAL OUTPUTS CONFIGURED FOR AUX RELAY CONTROL OUT1 OUT4 signals for relays GND ground ...

Page 35: ...1592022020 iCHILL 100D EVO QRG EN rel 2 0 23 02 2022 35 40 17 10 CONNECTION TO THE IEV22D OR IEV12D ELECTRONIC EXPANSION VALVE DRIVER ...

Page 36: ...1592022020 iCHILL 100D EVO QRG EN rel 2 0 23 02 2022 36 40 18 INSTALLING AND MOUNTING 18 1 MECHANICAL CHARACTERISTIC ...

Page 37: ... BOARDS VI613 PANEL CUT OUT The keyboard must be mounted on vertical panel with cut out 72x56 mm and screwed with two screws The IP65 can be reached with the gasket RGW V optional WALL MOUNTING use the vertical V KIT black white and grey as described in the following scheme ...

Page 38: ...ower cables and terminals Respect the maximum load current of each relay output Some contactors can produce very high electrical stresses on the relay contacts mounted in the device Dixell suggests to carefully check the technical documentation of the contactors and follow the instructions contained in this doumentation commercial documentation is not a reference for theese information To protect ...

Page 39: ...r Class II equipment 20 2 ANALOGUE INPUTS Number of inputs 5 NTC PTC D I 3 NTC PTC 4 20mA 0 5V D I Type of analogue input configurable via software parameter NTC 50T110 C 10KΩ 1 a 25 C PTC 50T150 C 990Ω 1 a 25 C Rathiometric 0 5 4 5V Current 4 20mA Digital input free contact Measurement range 50 C 110 C 58 F 230 F NTC probe 50 C 150 C 58 F 302 F PTC probe 0 bar 50 bar 0 psi 302 psi pressure probe ...

Page 40: ...D model Maximum load 5A 250Vac SPST 5 2 A Note Verify maximum current of the loads and maximum current of the common line of the relay 10A max There is double insulation between the digital outputs and the low voltage of the rest of the circuit Do not use different voltages for the two groups of relays Some contactors can produce very high electrical stresses on the relay contacts mounted in the d...

Reviews: