10.4 Ordinary certification location from CSA
The product has been examined and tested to determine that the design
meets the basic electrical, mechanical, and fire protection requirements by
CSA, a nationally recognized test laboratory (NRTL) as accredited by the
Federal Occupational Safety and Health Administration (OSHA).
10.5 Installing in North America
The US National Electrical Code
®
(NEC) and the Canadian Electrical Code
(CEC) permit the use of Division marked equipment in Zones and Zone
marked equipment in Divisions. The markings must be suitable for the area
classification, gas, and temperature class. This information is clearly defined
in the respective codes.
10.6 USA
I5 Intrinsically Safe (IS)
Certificate
[CSA] 80004152
Standards
ANSI/UL 60079-0-2013 (r2017), ANSI/UL 60079-11Ed. 6
(March 28, 2014), ANSI/UL 61010-1-2016 Ed. 3, ANSI/UL
50E-15 Ed. 2
Geo 10
Markings
Intrinsically safe for:
Class I, Division 1, Groups A, B, C, D T4;
Class I Zone 0, AEx ia IIC T4 Ga
Ex ia IIC T4 Ga
T4 (-20°C ≤ Ta ≤ +60°C)
when installed per Rosemount drawing 00GEO-1106;
IP66/67;
Geo 20
Markings
Intrinsically safe for:
Class I, Division 1, Groups A, B, C, D T4;
Class I Zone 0, AEx ia IIC T4 Ga
Ex ia IIC T4 Ga
T4 (-40°C ≤ Ta ≤ +70°C)
when installed per Rosemount drawing 00GEO-1006;
IP66/67, Type 4X;
Special Conditions for Safe Use (X):
1. Do not replace battery when explosive atmosphere is present.
2. Use only 00G45-9000-0001 batteries.
February 2020
Quick Start Guide
Quick Start Guide
25
Summary of Contents for Location Awareness
Page 20: ...4 Name Tag Quick Start Guide February 2020 20 Emerson com ...
Page 30: ...Quick Start Guide February 2020 30 Emerson com ...
Page 31: ...February 2020 Quick Start Guide Quick Start Guide 31 ...
Page 32: ...11 2 Location Awareness Anchor Quick Start Guide February 2020 32 Emerson com ...
Page 33: ...February 2020 Quick Start Guide Quick Start Guide 33 ...
Page 34: ...Quick Start Guide February 2020 34 Emerson com ...
Page 35: ...February 2020 Quick Start Guide Quick Start Guide 35 ...