background image

22

                                                                                                                                                                                                                      

ETL Model No.: CF995-1

Do not use water when cleaning your ceiling fan. It could

damage the motor or the blades and create the possibility

of an electrical shock.

                           

WARNING

!

IMPORTANT CARE INSTRUCTIONS

for your Ceiling Fan

Periodic cleaning of your new ceiling fan is the only

maintenance that is needed.
When cleaning, use only a soft brush or lint free cloth to

avoid scratching the finish.
Abrasive cleaning agents are not required and should be

avoided to prevent damage to finish.

9. Maintenance

This product is designed to use only those parts supplied

with this product and/or any accessories designated

specifically for use with this product by Emerson Electric

Co. Substitution of parts or accessories not designated

for use with this product by Emerson Electric Co. could

result in personal injury or property damage.

                           

WARNING

!

See your local Emerson dealer, www.emersonfans.com

or the Emerson Ceiling Fan Catalog for these Accessories:
• Ceiling Fan Wall Controls
• Downrod Extension Kits

10. Accessories

The use of any other control not specifically approved for

this fan could result in fire, shock and personal injury.

                           

WARNING

!

11. Remote Control Troubleshooting

Fan/Light Fails to Operate

• Check that the Light Switch is on.

• Check that the Battery is good

(blue indicator light should light when any button is

pressed).

• Check that the Receiver is wired properly.

Short Range

• If the Remote Control operates the Fan when close to it,

but does not operate it at a distance of 40 Feet, try

placing the Antenna Wire outside of the Ceiling Cover.

Summary of Contents for Laclede Eco LED CF995BS01

Page 1: ...CLEDE Eco LED 62 Ceiling Fan Owner s Manual CF995BS01 Brushed Steel CF995VNB01 Venetian Bronze Model Numbers Net Weight 34 6 Lbs Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com TRANSITIONAL ...

Page 2: ...nch circuit NOTE This fan is suitable for use with solid state speed controls NOTE All set screws must be checked and re tightened where necessary before installation CAUTION To Reduce The Risk Of Injury To Persons Install Fan So That The Blade Is At Least 2 1 Meters 7 Feet Above The Floor 1 Read your owner s manual carefully and keep it for future reference 2 Be careful of the fan and blades when...

Page 3: ... are missing call 1 800 654 3545 for replacement parts before proceeding 1 2 Remove the Fan Motor Assembly from the protective plastic bag Place the Fan Assembly into the lower foam pad with the bottom of the Motor facing up The upper foam pad serves as a holder for the Fan during the first stages of assembly PACKAGE CONTENTS 6 10 7 8 9 1 2 3 4 5 Part Description Quantity A Fan Motor Assembly 1 B ...

Page 4: ...rt of 22 7 kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiri...

Page 5: ...4 20 x 3 8 PAN HEAD SCREW WITH CAPTIVE LOCKWASHER Figure 3 3 2 Loosely attach One Blade Flange Assembly to the Motor Hub by securing the Two 1 4 20 x 3 8 Pan Head Screws with Captive Lockwasher supplied Figure 2 Make sure the Screws are loosely tightened for this step Repeat this procedure for other Four Blade Assemblies To reduce the risk of personal injury do not bend the blade flange when insta...

Page 6: ...lign the Two Loosened Screw Heads into the Key Hole Slots Rotate the Lower Light Fixture Clockwise to engage both Screws Tighten both Screws and reinstall the previously removed 8 32 x 5 16 Pan Head Screw to secure the Fixture Figure 6 NOTE Be careful not to pinch any wires or connectors between the lower light fixture and the lower light adapter plate A spare 8 32 x 5 16 Pan Head Screw is in the ...

Page 7: ...gn the Three Loosened Screw Heads into the Key Hole Slots on the Cover Rotate the Cover Clockwise to engage the Screw Heads Tighten the Screws and reinstall the previously removed Screw to secure the Cover Figure 8 NOTE Be careful not to pinch any wires or connectors between the lower light cover and the lower light fixture A spare 8 32 x 5 16 Pan Head Screw is in the hardware bag if needed STYROF...

Page 8: ...OSENED HANGER BALL 10 DOWNROD PIN GREEN GROUND WIRE Figure 10 10 DOWNROD TWO 80 MOTOR WIRES UNTWISTED Figure 11 3 11 Separate untwist and unkink the Two 80 Motor Wires Route the Two 80 Black and White Motor Wires through the 10 Downrod Figure 11 10 DOWNROD MOTOR COUPLER LOOSEN SET SCREWS 2 Figure 12 3 12 Loosen the Two Phillips Head Set Screws in the Motor Coupler for installation of the 10 Downro...

Page 9: ...s in the Motor Coupler and Downrod It is critical that the Clevis Pin in the Motor Coupler is properly installed and securely tightened RETIGHTEN TWO PHILLIPS HEAD SET SCREWS MOTOR COUPLER 10 DOWNROD Figure 14 3 14 While pulling up on the 10 Downrod retighten the Two Phillips Head Set Screws to secure the 10 Downrod in the Motor Coupler Figure 14 NOTE The Set Screws must be properly installed as d...

Page 10: ...g Cover is oriented correctly Figure 16 10 DOWNROD CEILING COVER Figure 16 3 17 Route the Two Motor Wires through the Hanger Ball Reinstall the Hanger Ball Figure 17 on the Downrod as follows Position the Pin through the Two Holes in the Downrod and align the Ball so the Pin is captured in the Groove in the top of the Hanger Ball Pull the Hanger Ball up tight against the Pin and securely tighten t...

Page 11: ...ontact 1 800 654 3545 for further assistance ETL Model No CF995 1 3 Ceiling Fan Assembly continued BLACK WIRE 6 TO 9 INCHES WHITE WIRE HANGER BALL 1 2 INCH Figure 18 3 18 The Fan comes with Black and White Wires that are 80 inches long Before installing the Fan measure up approximately 6 to 9 inches above top of Hanger Ball Downrod Assembly Figure 18 Cut off excess Wires and strip back insulation ...

Page 12: ...es are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING 4 1 Securely attach the Hanger Bracket to the Outlet Box using the Two Screws supplied with the Outlet Box Figure 22 Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not se...

Page 13: ... before wiring NOTE If you are not sure if the outlet box is grounded contact a licensed electrician for advice as it must be grounded for safe operation WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with t...

Page 14: ...WIRES Figure 27 5 4 After Connections have been made turn Wires upward and carefully push Wires into the Outlet Box with the White and Green Wires on one side of the Outlet Box and position the Black Wires on the other side of the Outlet Box Figure 27 Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do n...

Page 15: ...o the Threaded Studs and turn until Studs protrude through the holes in the Ceiling Cover Figure 29 Secure the Ceiling Cover in place by sliding Lockwashers over the Threaded Studs and installing the two Knurled Knobs supplied Figure 29 Tighten the Knurled Knobs securely until the Ceiling Cover fits snugly against the ceiling and the hole in the Ceiling Cover is clear of the Downrod 6 Final Assemb...

Page 16: ...15 Medium Base LED Bulbs supplied into the Upper Light Fixture Sockets Figure 30 LOWER LIGHT FIXTURE LOWER LIGHT FIXTURE SOCKETS 5 6 5 WATT A15 MEDIUM BASE LED LIGHT BULBS 5 Figure 31 6 4 Lower Light Bulb Installation Install the Five 6 5W A15 Medium Base LED Bulbs supplied into the Lower Light Fixture Assembly Sockets Figure 31 6 Final Assembly continued ...

Page 17: ...D SCREW LOOSEN TWO 8 32 x 5 16 PAN HEAD SCREWS LOWER LIGHT FIXTURE ASSEMBLY Figure 32 6 6 Place the Lower Glass Shade onto the Lower Light Cover Rotate the Glass Shade to engage the two loosened Screws in the Two Key Hole Slots Replace the previously removed 8 32 x 5 16 Pan Head Screw Tighten all Three Screws to secure the Lower Glass Shade to the Lower Light Assembl Install the Finial Nut finger ...

Page 18: ...s for dimming control of lights Set Switch to ON to allow for dimming of the lights Set Switch to I for no dimming of the lights NOTE If your Fan and Light go on and off without using your Control you may be getting interference from other remote units such as garage door openers car alarms or security systems To remedy this situations simply change the combination code in your Remote Control Tran...

Page 19: ...t be completed including the installation of the fan blades before testing of the remote control Your Remote Control has full control of your Fan and Light Figure 36 To turn the Fan ON or OFF press the Button POWER INDICATOR LIGHT FAN SPEED INCREASE DECREASE Figure 37 7 5 To set the desired Fan Speed press the Button to decrease the Speed and the to increase the Speed The LED Display will Light up...

Page 20: ...HT AIRFLOW BUTTON Figure 39 7 7 If Airflow is desired in the opposite direction press the Button on the Wall Control The fan must be operating at any Speed for the Reverse Button to function The blades will turn in the Opposite Direction and reverse the airflow Figure 39 Note If your fan and light go on and off without using your control you may be getting interference from other remote units such...

Page 21: ...nical support at 1 800 654 3545 if you have any questions about installation and operation of this ceiling fan Figure 40 8 Programming the Receiver Operating Frequency PROGRAMMING THE RECEIVER OPERATING FREQUENCY 8 1 Turn the Remote Control ON OFF Switch to the OFF position Restore Electricity to the Ceiling Fan Branch Circuit at the Circuit Breaker or Fuse Box Flip the Remote Control s ON OFF Swi...

Page 22: ... Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage WARNING See your local Emerson dealer www emersonfans com or the Emerson Ceiling Fan Catalog for these Accessories Ceiling Fan Wall Controls Downrod Extension Kits 10 Accessories The use of any other control not specifically approved for this f...

Page 23: ... are snug Not Over Tight 3 Fan wobbles 1 Setscrews in Motor Coupler are not 1 Raise Coupler Cover and tighten Set Screws securely excessively tightened securely 2 Set Screw in the Hanger Ball Downrod 2 Tighten the Setscrew in the Hanger Ball Downrod Assembly is loose Assembly 3 Screws securing Fan Blades to Motor 3 Check to be sure Screws which attach the Fan Blades are loose to the Motor are tigh...

Page 24: ...24 ETL Model No CF995 1 13 Repair Parts PARTS BAG 15 16 20 5 4 6 7 8 9 10 11 12 13 24 9 21 22 10 7 8 14 3 2 1 6 18 19 17 23 10 10 ...

Page 25: ...0 Parts Bag Containing 764458 CHRM 764458 BLOX 4 Pin Clevis 1 5 Clip Hairpin 1 6 Threaded Stud 8 32 x 1 1 4 2 7 Lockwasher External Tooth 8 2 8 Knurled Knob 8 32 2 9 Screw Washer Head 10 32 x 1 4 21 10 Screw Pan Head 1 4 20 x 3 8 with Captive Lockwasher 11 11 Screw Pan Head 8 32 x 5 16 1 12 Wire Connector 3 13 Balancing Kit 1 14 Ceiling Cover 1 764435 BS 764435 VNB 15 Motor Coupler Cover 1 764436 ...

Page 26: ...omply with the limits for a class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Howe...

Page 27: ...anship Loss or damage resulting from conditions beyond our reasonable control including without limitation unforeseeable operating environmental conditions repairs not made at Our factory or authorized service center use of parts or accessories not provided to You as part of this warranty by Our factory or authorized service center mishandling unreasonable use misuse abuse modifications or other d...

Page 28: ...ervice 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com Retain this manual for future use Air Comfort Products DIVISION OF EmErSON ElEctrIc cO 8100 W Florissant St louis mO 63136 Part No F40BP74790001 Form No BP7479 1 Revision 190204 ETL Model No CF995 1 Printed in China 02 19 ...