![Emerson FloBoss S600+ Instruction Manual Download Page 50](http://html.mh-extra.com/html/emerson/floboss-s600/floboss-s600_instruction-manual_102410050.webp)
S600+ Instruction Manual
4-12
I/O
Revised July-2017
Table 4-10. Raw Pulse Output Pin Connections for SKT-C
Pin
Function
24
Raw Output
5
Return
4.1.8 Frequency Inputs
The S600+ typically uses the three supported frequency inputs for
density transducer signals. Each input has an input range of 0 to 10
KHz. Jumpers on the module enable you to set the inputs to be AC- or
DC-coupled. Refer to
Figures 4-17
and
4-18
.
The frequency input channels use the SKT-B connector, which is
located on the backplate of the I/O module.
Table 4-11
shows the
frequency input pin connections.
Figure 4-17. Frequency Input Schematic (with IS Barrier and AC-Coupled)
Figure 4-18. Frequency Input Schematic (without IS Barrier and with DC-Coupled)
Note
:
The Micro Motion (previously Solartron) devices may still
have their previous manufacturer’s labels.
Summary of Contents for FloBoss S600+
Page 66: ...S600 Instruction Manual 4 28 I O Revised July 2017 This page is intentionally left blank ...
Page 114: ...S600 Instruction Manual A 8 Glossary Revised July 2017 This page is intentionally left blank ...
Page 150: ...S600 Instruction Manual C 28 Chromatographs Revised July 2017 2350 USA 2551 USA ...