![Emerson FloBoss S600+ Instruction Manual Download Page 45](http://html.mh-extra.com/html/emerson/floboss-s600/floboss-s600_instruction-manual_102410045.webp)
S600+ Instruction Manual
Revised July-2017
I/O
4-7
Note
:
You must connect the feed lines (such as pin 17 on SKT-B) to a
24 Volts dc source. The DIGIN lines (such as pin 13 on SKT-
B) expect typical “open collector” (referenced to GND)
connections.
Figure 4-9. Digital Input Schematic (Open Collector Device)
Figure 4-10. Digital Input Schematic (Relay)
Table 4-4. DIGIN Pin Connections for SKT-B
Pin
Function
13
DIGIN-CH1
14
DIGIN-CH2
15
DIGIN-CH3
16
DIGIN-CH4
17
RETURN CH1-4
18
DIGIN-CH5
19
DIGIN-CH6
Summary of Contents for FloBoss S600+
Page 66: ...S600 Instruction Manual 4 28 I O Revised July 2017 This page is intentionally left blank ...
Page 114: ...S600 Instruction Manual A 8 Glossary Revised July 2017 This page is intentionally left blank ...
Page 150: ...S600 Instruction Manual C 28 Chromatographs Revised July 2017 2350 USA 2551 USA ...