B.8 SPECIFICATIONS
Remote MVS101 Specifications
DIFFERENTIAL PRESSURE INPUT
Range
: 0 – 322 inches H2O (0 – 80 kPa)
Reference Accuracy:
±
0.1% of span (includes
linearity, hysteresis, and repeatability effects), for
spans from 1:1 to 10:1 turndown.
STATIC PRESSURE INPUT
Range:
0 – 1450 psia (0 – 10,000 kPa abs.)
Reference Accuracy:
±
0.1% of span (includes
linearity, hysteresis, and repeatability effects), for
spans from 1:1 to 10:1 turndown.
PROCESS TEMPERATURE INPUT
Type:
For platinum 100-ohm RTD
(conforming to
IEC 751 Class B), with
α
= 0.00385.
Range:
-50 to 350 °C (-58 to 662 °F).
Reference Accuracy:
±0.1%, exclusive of RTD
sensor error. Specification includes linearity,
hysteresis, and repeatability effects.
OUTPUT
Type:
RS-485 asynchronous serial communication
using Fisher protocol.
Rate:
9600 baud.
POWER
20 mA dc max. at 7.5 to 27 Vdc, supplied by ROC or
FloBoss.
ENVIRONMENTAL
Operating Temperature:
-40 to 75 °C (-40 to 167 °F).
Storage Temperature:
-40 to 85 °C (-40 to 185 °F).
Operating Humidity:
5 to 100% relative humidity,
non-condensing.
DIMENSIONS
Overall:
4.0 in. H by 5.1 in. W by 7.2 in. D (102
mm by 130 mm by 183 mm).
Conduit Connections:
Electronics head has two
1/2-inch NPT connections for conduit.
Process Connections:
Sensor body has two 1/4-
18 NPT connections on 2 1/8-inch (54 mm)
centers.
CONSTRUCTION
Sensor Body:
316 SST. Silicon oil filled.
Diaphragm:
Hastelloy C (NACE compliant).
Electronics Head:
urethane-painted die-cast
aluminum alloy, rated Type 4X.
MOUNTING
For pipestand mounting, mounts on 2-inch pipe
using
optional mounting bracket
. Can also
mount to wall/panel on 2.8-inch centers using
5/16” bolts and optional mounting bracket.
WEIGHT
7 lb. (3 kg).
APPROVALS
Approved by CSA for hazardous locations Class I,
Divi sion 1 (explosion proof), Groups C and D.
Also approved by CSA to IEC standards for
Class I, Zone 1 (Flameproof), Group IIB.
Summary of Contents for Fisher FLOBOSS 407
Page 6: ...FloBoss 407 Instruction Manual vi Rev 5 00 This page is intentionally left blank ...
Page 22: ...FloBoss 407 Instruction Manual 1 16 Rev 5 00 This page intentionally left blank ...
Page 134: ...FloBoss 407 Instruction Manual 4 24 Rev 5 00 This page is intentionally left blank ...
Page 184: ...FloBoss 407 Instruction Manual C 8 Rev 5 00 This page is intentionally left blank ...
Page 190: ...FloBoss 407 Instruction Manual G 6 Rev 5 00 This page is intentionally left blank ...
Page 199: ...FloBoss 407 Instruction Manual Rev 5 00 I 9 This page intentionally left blank ...