background image

W6866 

!

Type 63EG-98HM Pilot-Operated Relief Valve or 

Backpressure Regulator

WARNING

Failure to follow these instructions or 

to properly install and maintain this 

equipment could result in an explosion, 

fire and/or chemical contamination 

causing property damage and personal 

injury or death.
Fisher™ relief valves or backpressure 

regulators must be installed, operated 

and maintained in accordance with 

federal, state and local codes, rules 

and regulations and Emerson Process 

Management Regulator Technologies, 

Inc. (Emerson) instructions.
If a leak develops or if the outlet 

continually vents gas, service to the 

unit may be required. Failure to correct 

trouble could result in a hazardous 

condition. Only a qualified person must 

install or service the unit.
Installation, operation and maintenance 

procedures performed by unqualified 

personnel may result in improper 

adjustment and unsafe operation. Either 

condition may result in equipment 

damage or personal injury. Use qualified 

personnel when installing, operating and 

maintaining the Type 63EG-98HM 

Pilot-Operated Relief Valve or 

Backpressure Regulator.

Figure 1. 

Type 63EG-98HM Pilot-Operated Relief Valve or 

Backpressure Regulator

Introduction

Scope of the Manual

This manual describes and provides instructions and 

a parts list for the Type 63EG-98HM relief valve or 

backpressure regulator. Instructions and parts lists 

for other equipment used with this valve are found in 

separate manuals.

Product Description

The Type 63EG-98HM pilot-operated relief valve 

or backpressure regulator is used for gas or liquid 

applications. For applications up to 450°F / 232°C, 

the Type 63EG-98HM utilizes high temperature 

Ethylenepropylene (EPR) or Perfluoroelastomer 

(FFKM) elastomers for Class VI shutoff. If used in a 

corrosive service, Perfluoroelastomer (FFKM) and other 

elastomers are available options that offer superior 

resistance to heat and most corrosive chemicals. This 

unit is not an ASME certified device.

July 2019

Type 63EG-98HM

Instruction Manual

D102630X012

Summary of Contents for Fisher 63EG-98HM

Page 1: ...condition may result in equipment damage or personal injury Use qualified personnel when installing operating and maintaining the Type 63EG 98HM Pilot Operated Relief Valve or Backpressure Regulator Figure 1 Type 63EG 98HM Pilot Operated Relief Valve or Backpressure Regulator Introduction Scope of the Manual This manual describes and provides instructions and a parts list for the Type 63EG 98HM re...

Page 2: ...and any applicable standard limitation should not be exceeded 3 Fluorocarbon FKM diaphragm is limited to 300 psig 20 7 bar 4 Set pressure is defined as the pressure at which the pilot starts to discharge 5 Special low temperature constructions for process temperatures between 76 to 104 F 60 to 40 C are available by request The low temperature construction passed Emerson laboratory testing for lock...

Page 3: ...e pilot exhaust faster than it can be replaced through the pilot restriction This permits inlet pressure to unbalance the main valve plug and open the main valve As inlet pressure drops below set pressure the pilot control spring closes the pilot valve plug Loading pressure again builds up to close the main valve plug WARNING Installation Personal injury equipment damage or leakage due to escaping...

Page 4: ... Call a qualified personnel when installing operating and maintaining relief valves and backpressure regulators Before installing inspect the main valve pilot and tubing for any shipment damage or foreign material that may have collected during crating and shipment Make certain the body interior is clean and the pipelines are free of foreign material Apply pipe compound only to the external pipe t...

Page 5: ... the main valve and pilot WARNING Maintenance Relief valve and backpressure regulator parts are subject to normal wear and must be inspected and replaced as necessary The frequency of inspection and replacement of parts depends upon the severity of service conditions or the requirements of local state and federal regulations Due to the care Emerson takes in meeting all manufacturing requirements h...

Page 6: ...nge and valve body side tappings 4 Remove the upside down body flange key 2 if it was anchored on the body Lightly lubricate the cage seating surfaces of the valve body web and the body flange Install the body flange on the body key 1 and secure it evenly with the cap WARNING 1 Screws or stud bolts key 3 Install the pilot and its pipe nipple and connect the pilot tubing 2 Install the spring key 9 ...

Page 7: ... 11 and onto the body key 1 Tighten the cap screws key 16 finger tight only 12 To ensure proper slack in the diaphragm key 12 apply some spring compression by turning the adjusting screw key 15 clockwise Finish tightening the cap screws key 16 with 10 to 13 ft lbs 13 56 to 17 63 N m of torque Table 5 Type 63EG Main Valve Body Part Numbers Key 1 BODY MATERIAL END CONNECTION STYLE PART NUMBER NPS 2 ...

Page 8: ...able 6 11 Cage NPS 2 DN 50 body 316 Stainless steel Linear Cage 34B5838X012 416 Stainless steel Whisper Trim Cage 24A5707X012 316 Stainless steel Whisper Trim Cage 24A5707X022 NPS 3 DN 80 body 316 Stainless steel Linear Cage 34B5839X012 416 Stainless steel Whisper Trim Cage 24A5708X012 316 Stainless steel Whisper Trim Cage 24A5708X042 NPS 4 DN 100 body 316 Stainless steel Linear Cage 34B5840X012 4...

Page 9: ...012 Perfluoroelastomer FFKM 1F2629X0042 Ethylenepropylene EPR 1F2629X0032 24 Drive Screw 4 required 1A368228982 25 Flow Arrow Key Description Part Number 26 Nameplate 27 Travel Indicator Plug Steel NPS 2 3 and 4 DN 50 80 and 100 bodies 17B4894X012 NPS 6 DN 150 17B4893X032 Stainless steel NPS 2 3 and 4 DN 50 80 and 100 bodies 17B4894X022 NPS 6 DN 150 body 17B4893X032 29 Hex Nut for stainless steel ...

Page 10: ...2 302 Stainless steel ERCA00496A0 13 Nameplate 14 Diaphragm Protector PTFE if required 11A5136X012 Key Description Part Number 15 Adjusting Screw Use with all other springs GF05553X012 Use with 150 to 375 psig 10 3 to 25 9 bar spring ERAA02340A0 16 Cap Screw 8 required Steel ERCA00100A0 Stainless steel ERCA00100A1 17 Jam Nut Steel ERCA00380A0 18 Drive Screw 4 required ERAA01884A0 24 Machine Screw ...

Page 11: ... 27 36 34 35 37 35A3174 A A2812 4 24 15 26 11 2 12 21 1 27 16 9 31 20 13 14 17 3 24 25 Figure 4 Type 63EG Main Valve FIXED RESTRICTION CONTROL LINE CONNECTION EXHAUST Figure 5 Type 63EG Main Valve Trim Package Figure 6 Type 63EG 98HM Mounting Parts 11 Type 63EG 98HM ...

Page 12: ...gement Regulator Technologies Inc does not assume responsibility for the selection use or maintenance of any product Responsibility for proper selection use and maintenance of any Emerson Process Management Regulator Technologies Inc product remains solely with the purchaser APPLY 1 T THREAD LOCKER L1 GENERAL PURPOSE PTFE OR LITHIUM GREASE FOR O RINGS L2 ANTI SEIZE COMPOUND L4 GRAPHITE SEALANT FOR...

Reviews: