Emerson FB1100 Flow Computer Instruction Manual
D301752X012
August 2020
56
Service and Troubleshooting
Figure 4-3: Captive Fastening Screws
4.
Grasp the HMI module and remove it by gently pulling it straight out away from the unit.
5.
To replace the HMI module, line up the printed circuit board (PCB) with the slot on the back
and gently press it back on. Tighten the four captive fastening screws.
6.
Replace the end cap. Screw the end cap clockwise (eight full turns) until it is tightly sealed to
the enclosure. Re-attach the retaining clamp, if applicable (see
Section 2.6.1
).
4.5
Replacing the Main Battery Pack
Periodically you must replace the main battery pack. FBxConnect provides a battery life indicator to
show the number of days in use. In addition, if you use a lithium battery for main power, the Status
LED shows yellow when the battery is low and needs to be replaced.
WARNING
If lead acid battery voltage falls below 4.7V, the battery can no longer be recharged, and the
charging system considers the battery dead. You must replace the battery.