21
‐
Parameter
Name
Setting range
Min.
unit
Default
Mod.
11: Heatsink overheating (E011)
12: Reserved
13: Inverter overload (E013)
14: Motor protection (E014)
15: Reserved
16: EEPROM read or write fault
(E016)
17: Reserved
18: Reserved
19: Current detecting circuit fault
(E019)
20 ~ 23: Reserved
24: Motor tuning error (E024)
25: PG error (E025)
26: Overspeed protection (E026)
27: Reserved
28: Parameter setting error (E028)
29: Door width auto-learning error
(E029)
30: OD overtime error (E030)
31: CD overtime error (E031)
F9.05
DC Bus
Voltage (V) at
the latest fault
0 ~ 999V
1V
0V
*
F9.06
Output current
(A) at the
latest fault
0.00 ~ 99.99A
0.01A
0.00A
*
F9.07
Frequency
(Hz) at the
latest fault
0.00Hz ~ 128.00Hz
0.01Hz
0.00Hz
*
F9.08
Status of input
terminal at the
latest fault
0 ~ 127 (0: OFF
;
1: ON)
CD/OD/X5/X4/X3/X2/X1
1 0 *
F9.09
Status of
output
terminal at the
latest fault
0 ~ 7 (0: OFF
;
1: ON)
PC3/PC2/PC1
1 0 *
F9.10
High digits of
pulse counted
for door
position at
fault time
0 ~ 9999 (×10000)
1
0
*
F9.11
Low digits of 0 ~ 9999
1
0
*
www.novaelevator.com