12
‐
Parameter
Name
Setting range
Min.
unit
Default Mod.
F0.03
Running
direction
selection
0: same as direction preset by actual motor
wiring
1: reverse to direction preset by actual motor
wiring
1 0 ×
F0.04
Max.output
frequency
50.00Hz ~ 128.0Hz
0.01Hz 50.00Hz ×
F0.05 ~
F0.08
Reserved
7.2
OD
Operation
Parameters
F1
Parameter
Name
Setting range
Min.
unit
Default Mod.
F1.00
OD start creep time for speed
control
10 ~ 9999ms
1ms 500ms
○
F1.01
OD start creep distance for
distance control
pulse number (door width)
0
0
○
F1.02
OD start creep speed
1.00 ~ 25.00Hz
0.01Hz 2.50Hz
○
F1.03
OD Acc time
0.1 ~ 3600s
0.1s
3.5s
○
F1.04
OD reference frequency
0.00 ~ F0.04 max frequency
0.01Hz 14.00Hz
○
F1.05
Rush hour operation OD speed 0.00 ~ F0.04 max frequency
0.01Hz 14.00Hz
○
F1.06
OD speed decrease point in
distance control
pulse number (door width)
1
1000
○
F1.07
OD Dec time
0.1 ~ 3600s
0.1s
3s
○
F1.08
OD ending creep speed
0 ~ 15.00Hz
0.01Hz 2.5Hz
○
F1.09
OD position limit in distance
control
1 ~ 9999 (pulse number)
1
250
○
F1.10
Switching point of OD
complet maintaining torque
0.0% ~ 100.0% (motor rated
torque)
0.1% 45.0%
○
F1.11
OD complet maintaining
torque
0.0% ~ 100.0% (motor rated
torque)
0.1% 45.0%
○
F1.12
OD operation curve selection
in distance control
0: selecting manually preset
curve
1: selecting optimum curve by
auto-learning
1 0 ×
F1.13
OD optimum curve correction
factor
3.0% ~ 15.0% (door width)
0.1% 10.0%
○
F1.14 ~
F1.15
Reserved
7.3
CD
Operation
Parameters
F2
Parameter
Name
Setting range
Min.
unit
Default Mod.
www.novaelevator.com