14
‐
Parameter
Name
Setting range
Min.
unit
Default Mod.
F3.06
Position of safety edge lift signal
output
0% ~ 40.0% (door width)
0.1% 10.0% ×
F3.07
Function selection of OD upon
CD obstruction
0: stop; 1: open the elevator
door
1 1 ×
F3.08
CD obstruction sensitivity
0 ~ 150.0% (motor rated
torque)
0.1% 100.0%
○
F3.09
Dec time upon CD obstruction 10 ~ 2500ms
1ms 300ms
○
F3.10
OD obstruction sensitivity
0 ~ 150.0% (motor rated
torque)
0.1% 0%
○
F3.11
Maintaining time for complete
OD in demo mode
1 ~ 3600s
1s
2s
○
F3.12
Maintaining time for complete
CD in demo mode
1 ~ 3600s
1s
2s
○
F3.13
Preset CD/OD times in demo
mode
0 ~ 9999
1
0
○
F3.14
CD/OD times record in demo
mode
0 ~ 9999
1
0
○
F3.15
Auto reset times upon fault
0 ~ 100
1
0
×
F3.16
Torque enhance coefficient
100% ~ 350%
1%
115%
×
F3.17 Fan
control
0: fan does not start during
inverter operation
1: fan starts when heatsink
temperature is higher than
65°C during inverter
operation
2: fan starts during inverter
operation
1 0 ×
F3.18
Percentage or pulse number
selection
0: F1.01, F1.06, F1.13,
F2.01, F2.06 and F2.14 are
percentages.
1: F1.01, F1.06, F1.13,
F2.01, F2.06 and F2.14 are
numbers
0 1 ×
7.5
Door
Width
Self
‐
learning
Parameters
F4
Parameter
Name
Setting range
Min.
unit
Default Mod.
F4.00 PG
type
0: 24V incremental PG
1: UVW incremental PG (5V)
1 0
×
F4.01
Pulse number per revolution
0 ~ 4000
1
500
×
www.novaelevator.com