1592040000 XR30-60-70T EN v1.3 2020.08.26
XR30-60-70T
38/40
FEATURES
DESCRIPTION
Motor load ¼ HP (NO), 120Vac, 30K cycles
Pilot duty B300 (NO), 30K cycles
oA3 (*)
SPST 5A,
250Vac
Resistive load 5A, 120/240Vac, 50K cycles
Motor load 240Vac, 1.9FLA/11.4LRA, 30K cycles
Pilot Duty B300, 30K cycles
5(1)A, 230Vac, 50K cycles
oA4 (**)
SPST 8A,
250Vac
Resistive load 10A (NO), 120/240Vac, 30K cycles
Motor load ½ HP (NO), 240Vac, 30K cycles
Motor load ¼ HP (NO), 120Vac, 30K cycles
Pilot duty B300 (NO), 30K cycles
8(3)A (NO), 230Vac, 50K cycles
Maximum ampacity on common
terminal “Line” (for oAx)
16A
I/O port
HOT-KEY: MAX voltage allowed is 5 VDC. DO NOT CONNECT ANY EXTERNAL POWER SUPPLY
Purpose of control
Operating control
Construction of control
Incorporated control, intended to be used in Class I or Class II equipment
Approvals
R290/R600a: relays tested according to IEC EN60079:0 and IEC EN60079:15
IEC/EN 60730-1; IEC/EN 60730-2-9
UL 60730-1; UL 60730-2-9
CAN/CSA E60730-1; CAN/CSA E60730-2-9