background image

1598024xxx XR30CX VST GB r1.0 2011.01.21.doc

XR30CX

4/4

Power absorption:

3VA max.

Display:

3 digits red LEDs, 14.2 mm high.

Digital input:

free voltage contact.

Analogue Input:

a PT1000 or PTC probe, set via parameter.

Relay outputs:

Compressor:

20(8)A, 250Vac.

Alarm:

SPDT 8(3)A, 250Vac.

Connectors for external backup battery (only for battery-backup model)

.

Data storing:

on the non-volatile memory (EEPROM).

Kind of action:

1B.

Pollution degree:

2.

Software class:

A.

Rated impulsive voltage:

2500V.

Overvoltage Category:

II.

Operating temperature:

0÷60°C.

Storage temperature:

-30÷85 °C.

Relative humidity:

20

85% (no condensing).

Measuring and regulation range:

Pt1000 probe:

-100÷100°C (-148÷212°F).

PTC probe:

-55÷150°C (-67÷302°F).

Resolution:

0.1°C or 1°C or 1°F (selectable).

Accuracy (ambient temp. 25°C):

±0.7 °C ±1 digit.

Only for battery backup model:

Type of battery:

6Vdc, 1.2Ah.

Charging time:

94hours.

15. CONNECTIONS

15.1 XR30CX -4S1C1 (7020115)

15.2 XR30CX -5S1C1 WITH BATTERY BACKUP (7020122)

15.3 XR30CX -5S1C1 WITHOUT BATTERY BACKUP (7020110)

16. DEFAULT SETTING VALUES

Label

Name

Range

No batt.

backup

With batt.

backup Level

SEt

Set point

LS ÷ US

-62

-82

- - -

HY

Differential

[0.1

25.5°C]

[1

255°F]

[1°C]

[1°F]

[1°C]

[1°F]

Pr1

LS

Minimum set point

[-100,0°C ÷ SET]

[-148°F ÷ SET]

[-63°C]

[-81°F]

[-95°C]

[139°F]

Pr2

US

Maximum set point

[SET ÷ 150,0°C]

[SET ÷ 302°F]

[-30°C]

[-22°F]

[-60°C]

[-76°F]

Pr2

ot

Thermostat probe calibration

[-12

12°C]

[-120

120°F]

[0°C]

[0°F]

[0°C]

[0°F]

Pr1

odS

Outputs delay at start up

0 ÷ 255 min

0

0

Pr2

AC

Anti-short cycle delay

0

50 min

5

5

Pr1

CCt

Continuous cycle duration

0.0 ÷ 24h 00min, res. 10min

0.0

0.0

Pr2

CCS

Set point for continuous cycle

[-100 ÷ 150°C]

[-148 ÷ 302°F]

[-62°C]

[-79°F]

[-82°C]

[-115°F]

Pr2

Con

Compressor  ON  time  with  faulty

probe

0

255 min

60

60

Pr2

CoF

Compressor  OFF  time  with  faulty

probe

0

255 min

5

5

Pr2

CH

Kind of action

CL=cooling; Ht= heating

CL

CL

Pr2

CF

Temperature measurement unit

°C; °F

°C

°C

Pr2

rES

Resolution

in = integer; dE = dec.point

in

in

Pr2

dLY

Display temperature delay

0 ÷ 20min 00s, res. 10s

0.0

0.0

Pr2

idF

Interval between defrost cycles

1

120 hours

0

0

Pr1

MdF

(Maximum) length for defrost

0

255 min

0

0

Pr1

dFd

Displaying during defrost

rt; it; SEt; DEF

rt

rt

Pr2

dAd

MAX display delay after defrost

0 ÷ 255 min

0

0

Pr2

ALC

Temperature alarms configuration

rE= related to set

Ab = absolute

rE

rE

Pr2

ALU

MAXIMUM temperature alarm

[Set

110°C]

[Set ÷ 230°F]

[15°C]

[59°F]

[15°C]

[59°F]

Pr1

ALL

Minimum temperature alarm

[-100°C

Set]

[-148°F

Set]

[50°C]

[122°F]

[50°C]

[122°F]

Pr1

AFH

Differential for temperature alarm

recovery

[0.1°C ÷ 25.5°C]

[1°F÷45°F]

[1°C]

[1°F]

[1°C]

[1°F]

Pr2

ALd

Temperature alarm delay

0

255 min

0

0

Pr2

dAo

Delay of temperature alarm at start

up

0

23h 50min, res. 10min

1.3

1.3

Pr2

tbA

Alarm relay disabling

n; Y

Y

Y

Pr2

Aro

Alarm  relay  activation  with  power

failure

n; Y

Y

Y

Pr2

ALF

Alarm  relay  activation  for  all  the

alarms

n; Y

Y

Y

Pr2

bon

Time of buzzer restart after muting,

in case of alarm duration

0 ÷ 30 min

30

30

Pr2

AoP

Alarm relay  polarity  (oA1=ALr)

oP; CL

CL

CL

Pr2

i1P

Digital input polarity

oP=opening; CL=closing

CL

CL

Pr1

i1F

Digital input configuration

EAL; bAL; PAL; dor;

dEF; Htr, AUS

AUS

AUS

Pr1

did

Digital input alarm delay

0 ÷ 255 min

15

15

Pr1

nPS

Number  of  activation  of  pressure

switch

0 ÷ 15

15

15

Pr2

odc

Compress status when open door

no; FAn; CPr; F_C

no

no

Pr2

rrd

Regulation restart with door open

alarm

n; Y

Y

Y

Pr2

HES

Differential for Energy Saving

[-30°C ÷ 30°C]

[-54°F÷54°F]

[1°C]

[1°F]

[1°C]

[1°F]

Pr2

Adr

Serial address

0 ÷ 247

1

1

Pr2

PbC

Kind of probe

PtM; PtC

PtM

PtM

Pr2

onF

on/off key enabling

nU; oFF; ES

nU

nU

Pr2

rSE

Real set point value

actual set

--

--

Pr2

rEL

Software release

--

--

--

Pr2

Ptb

Map code

--

--

--

Pr2

Summary of Contents for Dixell XR30CX-4S1C1

Page 1: ...estriction of the use of certain hazardous substances in electrical and electronic equipment RoHS directive This drawing is the property of A S Vestfrost and must not be copied passed on to or otherwise used by any person without the express consent of A S Vestfrost Date Last modification Init Denne vare er specificeret ved nedenstående datablad Med forudgående skriftlig tilladelse fra Vestfrost k...

Page 2: ...the digital input can operate as third temperature probe The battery backup version is also provided with an input for external battery It is used to supply the controller in case of main voltage failure By using the HOT KEY input output port is possible to upload a new parameter map from program the controller or save the actual parameter map to an external memory device named HOTKEY memory Moreo...

Page 3: ...0 1 25 5 C 1 255 F intervention differential for set point Compressor Cut IN is Set Point differential HY Compressor Cut OUT is when the temperature reaches the set point LS Minimum set point 100 C SET 148 F SET it sets the minimum value for the set point US Maximum set point SET 150 C SET 302 F it sets the maximum value for set point ot Thermostat probe calibration 12 0 12 0 C 120 120 F allows to...

Page 4: ...ing function allows to change the set point value as the result of the SET HES parameter sum This function is enabled until the digital input is activated 8 8 DIGITAL INPUTS POLARITY The digital input polarity depends on the i1P parameter i1P CL the input is activated by closing the contact i1P OP the input is activated by opening the contact 9 TTL SERIAL LINE FOR MONITORING SYSTEMS It is possible...

Page 5: ... 60 Pr2 CoF Compressor OFF time with faulty probe 0 255 min 5 5 Pr2 CH Kind of action CL cooling Ht heating CL CL Pr2 CF Temperature measurement unit C F C C Pr2 rES Resolution in integer dE dec point in in Pr2 dLY Display temperature delay 0 20min 00s res 10s 0 0 0 0 Pr2 idF Interval between defrost cycles 1 120 hours 0 0 Pr1 MdF Maximum length for defrost 0 255 min 0 0 Pr1 dFd Displaying during ...

Reviews: