Interface requirements
Table 2-3:
Requirements
Description
Flange type
The mechanical connections for Models 762,
763, 765, 766 and 767 control valve NPS 2 to 16
are standard class 150, 300 and 600 ANSI R.F.
flanges, which are available only in carbon steel.
Other types of flange connections are available
per customer request for Daniel control valves.
For other ANSI ratings or flanges consult the fac-
tory engineers. For maximum working pressures
at intermediate temperatures refer to ANSI
B16.5.
WARNING!
FLANGE SIZE HAZARD
Customers must choose the appropriate size material of the flange for their piping
requirements.
Choosing an incorrect flange may cause a pressure leak, resulting in death or serious injury.
2.2.2
Requirements and limitations for installation
NOTICE
Comply with local government regulations and company requirements.
See
NOTICE
Flush lines to remove welding bead, pipe scale, etc.
Operating conditions and specifications
User manual
47
Summary of Contents for Daniel 762
Page 8: ......
Page 12: ...Plan 2 Daniel Models 762 763 765 766 and 767 Control Valves ...
Page 47: ...Models 762 763 765 766 and 767 Control Valves NPS 16 Figure 1 6 Introduction User manual 37 ...
Page 52: ...Introduction 42 Daniel Models 762 763 765 766 and 767 Control Valves ...
Page 72: ...Prepare the control valve for use 62 Daniel Models 762 763 765 766 and 767 Control Valves ...
Page 74: ...Install 64 Daniel Models 762 763 765 766 and 767 Control Valves ...
Page 82: ...Installation prerequisites 72 Daniel Models 762 763 765 766 and 767 Control Valves ...
Page 88: ...Testing the product 78 Daniel Models 762 763 765 766 and 767 Control Valves ...
Page 89: ...Part III Operate Operate User manual 79 ...
Page 90: ...Operate 80 Daniel Models 762 763 765 766 and 767 Control Valves ...
Page 96: ...Maintain 86 Daniel Models 762 763 765 766 and 767 Control Valves ...
Page 112: ...Decommission 102 Daniel Models 762 763 765 766 and 767 Control Valves ...
Page 113: ...Decommission User manual 103 ...
Page 114: ...Decommission 104 Daniel Models 762 763 765 766 and 767 Control Valves ...
Page 115: ...Decommission User manual 105 ...